Multi Variable Air Conditioners Compact Cassette Type Indoor Unit 

1 Safety Precautions   

 

(1)  This product can`t be installed at corrosive, inflammable or explosive environment or the place 

with special requirements, such as kitchen. Otherwise, it will affect the normal operation or 

shorten the service life of the unit, or even cause fire hazard or serious injury. As for above 

special places, please adopt special air conditioner with anti-corrosive or anti-explosion 

function. 

(2)  Follow this instruction to complete the installation work. Please read this manual carefully 

before turning on or repairing the unit. 

(3)  Installation should be conducted by the dealer or qualified personnel. Please do not attempt to 

install the air conditioner by yourself. Improper installation may lead to water leakage, electric 

shock or fire hazard, etc. 

(4)  Before installation, please check whether the power supply is complied with that specified on 

the nameplate and check the safety of the power supply. 

(5)  The air conditioner must be grounded reliably for avoiding electric shock. Please do not 

connect the earthing wire to gas pipe, water pipe, lightning rod or telephone line. 

(6)  Be sure to use special accessories and parts for installation to prevent water leakage, electric 

shock and fire hazard, etc. 

(7)  If refrigerant leakage happens, please ventilate the room immediately. 

(8)  Diameter of power cord should be large enough. The damaged power cord and connection 

wire must be replaced with special cables. 

(9)  When the power cord is connected, please fix the electric box cover properly to avoid safety 

accidents. 

(10)   Never fail to comply with the nitrogen-charging welding process. Do charge nitrogen when 

welding the pipes. 

(11) Never short circuit or cancel the pressure switch to prevent unit damage. 

(12) As for the unit controlled by the wired controller, connect the wired controller well firstly and 

then energize the unit; otherwise, the unit can’t operate normally. 

(13) When installation is finished, please check whether the drainage pipes, pipelines and electric 

wires are connected correctly to avoid water leakage, refrigerant leakage, electric shock or 

fire, etc. 

(14) Do not insert fingers or objects into air outlet or air return grille. 

(15) Open the door and window frequently to keep good ventilation for avoiding oxygen deficit 

when gas heater or oil heater is used in the room. 

(16) Never plug in or unplug the power plug directly to turn on or turn off the air conditioner.     

(17) Once the air conditioner is turned on, it can be turned off only after it has operated for 5min at 

least; otherwise, it will affect the oil return of compressor. 

(18) Do not allow children to operate this air conditioner. 

(19) Do not operate this air conditioner with wet hands. 

(20) The air conditioner can be cleaned only when it has been turned off and the power has been 

cut off; otherwise, it may cause electric shock or injury. 

(21) Never spray or flush water towards the air conditioner; otherwise, malfunction or electric shock 

may happen. 

(22) Do not expose the air conditioner to the moist or corrosive environment. 

(23) Put through the power 8 hours in advance before operation. Do not cut off the power when the 

air conditioner stops operation for only about one night (protect the compressor). 

(24) Volatile liquid, such as diluent or gasoline, will damage the appearance of air conditioner. Only 

soft dry cloth and wet cloth dipped with neutral detergent can be used to clean the outer case 

of air conditioner. 

(25) Under cooling mode, please don't set the room temperature too low; keep the temperature 

difference between indoor and outdoor within 5°C (41°F). 

(26) If there are any abnormal circumstances (such as burning smell, etc.), please turn off the unit 

and cut off the main power supply immediately, and then contact 

Lennox

 appointed service 

center. If those abnormal circumstances still exit, the unit may be damaged and it may lead to 

electric shock or fire hazard. 

(27) Do not repair the unit by yourself. Wrong maintenance may cause electric shock or fire hazard. 

Please contact 

Lennox

 appointed service center for help. 

Summary of Contents for VRF VE8C005C432P

Page 1: ...l Compact 8 Way Cassette Thank you for selecting LENNOX air conditioners Please read this manual carefully before operation and keep it for further reference VE8C005C432P VE8C007C432P VE8C009C432P VE8...

Page 2: ......

Page 3: ...te normally please contact our service center as soon as possible and provide the following information 1 Content on the nameplate model number cooling capacity production code ex factory date 2 Malfu...

Page 4: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Page 5: ...Testing 9 4 4 Locking Joint Installation 13 4 5 Panel Installation 14 4 6 Installation of Wired Controller 16 5 Wiring Work 16 5 1 Connection of Wire and Patch Board Terminal 16 5 2 Power Cord Connect...

Page 6: ...te normally 13 When installation is finished please check whether the drainage pipes pipelines and electric wires are connected correctly to avoid water leakage refrigerant leakage electric shock or f...

Page 7: ...on 2 1 Names of Key Components Fig 2 1 1 No 1 2 3 4 Name Drainage device Drainage Pipe Air flow flap Connection Pipe 2 2 Rated Working Condition Indoor Side Condition Outdoor Side Condition Dry Bulb T...

Page 8: ...ling off 12 Fastener 200mm 4 To fasten the sponge 13 Bolt with Washer 4 To fix the installation paperboard on the unit 14 Enswathement 2 Used for winding the pipe connecting the indoor and outdoor uni...

Page 9: ...t shall be installed in accordance with national standards or local regulations 2 Only qualified personnel can carry out installation work please contact with local dealer before installation 3 Make s...

Page 10: ...mmunication Wire between Indoor Unit and Indoor Unit or Outdoor Unit Fig 3 3 2 Material Type Total Length L m ft of Communication Cable between Indoor Unit and Indoor Outdoor Wire size mm2 AWG Materia...

Page 11: ...ture of 40 C 104 F 4 The circuit breaker specification in above sheet is based on ambient temperature of 40 C 104 F If the working condition is different please adjust it according to the specificatio...

Page 12: ...temporarily Assemble suspension bolt on the expansion bolt attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer from upper and lower sides of the hange...

Page 13: ...screwed joint and then tighten the flaring nut with hand as shown in Fig 4 2 1 2 Use a torque wrench to tighten up the flaring nut until the wrench gives out a click sound Fig 4 2 1 Pipe diameter mm i...

Page 14: ...he following Fig 4 3 1 and arrange insulation to the drainage pipe Improper installation may lead to water leakage and damp the furniture and other things in the room 7 You can buy normal hard PVC pip...

Page 15: ...ected to vertical pipe in the same level please select the connection way as shown in following figure 1 Three way connection of drainage pipe joints Fig 4 3 3 2 Connection of downspout elbow Fig 4 3...

Page 16: ...e less than C as shown in Fig 4 3 7 Unit mm inch Fig 4 3 7 Unit mm inch Model A B C 225 8 7 8 975 38 3 8 925 36 7 16 11 During the installation distance from soft drain pipe to the gasket is C when th...

Page 17: ...p etc 2 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check the draining through the drain socket 3 If communic...

Page 18: ...ed to be fixed through the side panel locking connector The fixing process is as follows 1 Remove the locking joint bracket from the side panel Fig 4 4 1 2 Attach the locking joint to the locking join...

Page 19: ...ion 1 Improper decorative panel installation could cause the following problems Fig 4 5 1 2 Ensure that it s clearance free between decoration panels and ceiling board after installation if not please...

Page 20: ...keep the mark and fittings on the same corner as shown in Fig 4 5 4 Fig 4 5 4 2 Adjust the position of panel to make the panel holes fix at the holes on the units 3 Fix the 4 screws at the two side of...

Page 21: ...y read the wiring diagram before carry out the wiring work incorrect wiring could cause malfunction or even damage the unit 3 The unit should be powered by independent circuit and specific socket 4 Th...

Page 22: ...terminal board 3 Insert the wire into the ring tongue terminal and tighten by crimping tool 4 Use the screwdriver for tightening the terminal Unit mm inch Fig 5 1 1 Fig 5 1 2 5 2 Power Cord Connection...

Page 23: ...shown in Fig 5 3 1 Fig 5 3 1 Fig 5 3 2 4 Fix the communication cable with clamp of electric box 5 For more reliable communication make sure connect the terminal resistor to the most downstream IDU of...

Page 24: ...2 2 Wired controller is connected to H1 H2 3 One indoor unit can connect two wired controllers that must be set as master one and slave one 4 One wired controller can control 16 indoor units in maximu...

Page 25: ...oth dipped in neutral detergent 6 Please contact after sales service staff if there is abnormal situation 6 1 Cleaning of Filter 1 Remove the filters from inlet of IDU Use a vacuum cleaner to remove d...

Page 26: ...rature Sensor Error dL Indoor Unit CO2 Sensor Error L5 Freeze Protection d4 Inlet Pipe Temperature Sensor Error dE Capacity DIP Switch Setting Error L7 No Master Indoor Unit Error d6 Outlet Pipe Tempe...

Page 27: ...t temperature is higher than 43 109 Poor cooling effect The filter is dirty or blocked Too heavy heat load of room e g too many people Door or windows is open Air inlet and outlet of IDU are blocked S...

Page 28: ...t us at 1 305 718 2901 lennoxglobalhvac lennoxintl com C 2020 Lennox Industries Inc For a complete list of the registered and common law trademarks owned by Lennox Industries Inc please visit www lenn...