TABLE 21
Maximum Allowable Intake or Exhaust Vent Length in Feet
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe
size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calculation.
Standard Termination at Elevation 0 - 4500 ft
Number Of 90° El
bows Used
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
040
060
080
040
060
080
040
060
080
1
81
66
44
115
115
93
138
137
118
2
76
61
39
110
110
88
133
132
113
3
71
56
34
105
105
83
128
127
108
4
66
51
29
100
100
78
123
122
103
5
61
46
24
95
95
73
118
117
98
6
56
41
19
90
90
68
113
112
93
7
51
36
14
85
85
63
108
107
88
8
46
31
n/a
80
80
58
103
102
83
9
41
26
75
75
53
98
97
78
10
36
21
70
70
48
93
92
73
TABLE 21 Continued
Maximum Allowable Intake or Exhaust Vent Length in Feet
Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size.
Concentric Termination at Elevation 0 - 4500 ft
Number Of 90° El
bows Used
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
040
060
080
040
060
080
040
060
080
1
73
58
42
105
105
89
121
121
114
2
68
53
37
100
100
84
116
116
109
3
63
48
32
95
95
79
111
111
104
4
58
43
27
90
90
74
106
106
99
5
53
38
22
85
85
69
101
101
94
6
48
33
17
80
80
64
96
96
89
7
43
28
12
75
75
59
91
91
84
8
38
23
n/a
70
70
54
86
86
79
9
33
18
65
65
49
81
81
74
10
28
13
60
60
44
76
76
69