NOTE:

For 81M26 single stage heat

pump applications, place a jumper
between the W1 and Y1 terminals.

7

Connect wiring between unit and 
furnace. For Model 81M27
(2H/2C furnace applications):

8

Replace cover on thermostat.
Turn on power to unit and proceed
with programming per instructions on
the display or in the user’s manual.

11

Connect wiring between unit and 
heat pump. For Model 81M28
(2H/2C heat pump applications):

9

To set your name and phone 
number into the thermostat press
MENU, select INSTALLER 
SETTINGS, and CONTACT 
INFORMATION. The screen at the
bottom left should appear.
To enter your name press EDIT.
Use the UP or DOWN button to
scroll through the characters.
(DOWN gets you to the letters
faster.) After each letter press NEXT.
When you are done entering your
name, press ACCEPT.

Connect wiring between the 
thermostat and the outdoor 
sensor (46M98), if used. Use twisted
pair wiring (84X49) with a maximum
length of 300 feet (or 100m).

Seal the hole in the wall with a suit-
able material to prevent drafts from
entering the thermostat case.

10

NOTE: If the SignatureStat is being used 

in conjunction with the G50UHI 
furnace, you will need Lennox relay
#45H03.

If the SignatureStat is being used in
conjunction with any other furnace
that uses a single-speed, multi-tap
indoor blower, you will need Lennox
Indoor Blower Control Kit #40K58.

If the SignatureStat is being used in
a dual fuel application, you will need
dual fuel tempering kit #67M41.

Now enter your phone number.
Use the UP and DOWN arrow to
select the first number. Press NEXT.
When you have completed entering
your phone number, press ACCEPT.

The screen will return to the
INSTALLER SETTINGS. Finish 
setting the thermostat for the 
application.

Y1

R

C

E/W1

H O B G

Furnace

Thermostat

C - Common 24 VAC
R - System transformer
Y1 - 1st stage cooling
W1- 1st stage heating
W2- 2nd stage heating
Y2 - 2nd stage cooling
L

- System check

O - Cool active reversing valve
B - Heat active reversing valve
G - Fan relay
D - Dehumidification relay
H - Humidification relay

TERMINAL DESIGNATIONS

W2

D

Y2

C

C

H

R

Y1

W1

W2

Y2

L

G

L

B

O

* Please refer to furnace

installation manual for
proper terminations

Note: To avoid electrical problems, use the system transformer for both

the thermostat and humidifier.

81M27

Humidifier

Wiring Terminals*

DS

Y1

R

C

E/W1

H O B G

Heat Pump

Wiring

Terminals*

Thermostat

C - Common 24 VAC
R - System transformer
Y1 - Compressor output
W1- Emergency heat relay
W2- 2nd stage heating
Y2 - 2nd stage cooling
L

- System check

O - Cool active reversing valve
B - Heat active reversing valve
G - Fan relay
D - Dehumidification relay

(to DS terminal)

H - Humidification relay

(to Humidifier)

TERMINAL DESIGNATIONS

W2

D

Y2

C

C

H

R

Y1

E

W2

Y2

G

L

B

L

O

DS

* For most applications, E/W1 should

be jumpered to W2.

* Please refer to heat pump installation

manual for proper terminations.

Note: To avoid electrical problems, use the system transformer for both

the thermostat and humidifier.

81M28

Humidifier

Set Your Name

Set Your Phone Number

Y1

R

C

E/W1

H O B G

Heat

Pump

Terminals*

Wiring

Thermostat

C - Common 24 VAC
R - System transformer
Y1 - 1st stage cooling
W1- 1st stage heating
W2- not used
Y2 - not used
L

- System check

O - Cool active reversing valve
B - Heat active reversing valve
G - Fan relay
D - Dehumidification relay
H - Humidification relay

TERMINAL DESIGNATIONS

W2

D

Y2

C

C

H

R

Y1

W1

L

G

L

B

O

* Please refer to heat pump

installation manual for
proper terminations

Note: To avoid electrical problems, use the system transformer for both

the thermostat and humidifier.

81M26

Humidifier

DS

Jumper

CONTACT INFORMATION

BACK

EDIT

ACCEPT

NEXT

CONTACT INFORMATION

LENNOX

CONTACT INFORMATION

LENNOX

ACCEPT

NEXT

1

ACCEPT

NEXT

CONTACT INFORMATION

LENNOX

1-555-555-1212

12

13

111-318E

www.lennox.com

504,683M