Lennox PureAir PCO-12C-2 Installation And Maintenance Instructions Manual Download Page 6

6

Maintenance

METAL INSERT & LAMP REPLACEMENT

Replace metal insert and lamps* every 24 months.
Replace insert more frequently if you notice a sig-
nificant drop in odor removal efficiency.

If you find that you need to replace the insert more
frequently than every 24 months, consider source
reduction and/or ventilation to reduce the levels of
contaminants in your home (see Homeowners IAQ
Guide for additional recommendations).

* Lamps will continue to glow at the end of the 24
months. However, their output efficiency will have
degraded to the point that they must be replaced to
assure effective performance of your PureAir™ unit.

1. Unplug the power cord and remove the access

door.

2. Slide out PCO-12C/20C assembly.

3. Remove metal insert.

4. Twist/rotate each lamp approximately 1/4 turn to

remove from sockets.

5. Install new lamps making sure to snap them

completely into the sockets and twist/rotate
lamp approximately 1/4 turn. Use gloves or cloth
to avoid fingerprints on lamps. (See page 3.)

MERV 9 PLEATED FILTER

The pleated filter should be replaced every 12
months. More frequent filter changes may be
required in situations with high dust or dirt loads.

1. Unplug the power cord and remove the access

door.

2. Partially slide out the PCO-12C/20C assembly. 

3. Remove the pleated filter and replace with the

same MERV 9 filter. (Performance of PCO-
12C/20C will be dramatically affected if improper
filter is installed.)

4. Slide assembly back into cabinet and install access

door.

5. Reconnect power cord.

6. Verify that the lamps are illuminated.

METAL INSERT/LAMP REPLACEMENT(Cont'd)

6. Install new metal insert.

7. Slide assembly back into cabinet and install

access door.

8. Reconnect power cord.

9. Verify that the lamps are illuminated.

Note:

DO NOT WASH metal insert. Washing will

destroy the titanium dioxide catalyst that coats the
insert surface.

Note:

If the system has been operated for a period

of time without the lamp(s) being illuminated (such
as at startup or with a failed lamp), an odor may
occur when lamps are (re)started. This symptom is
considered to be typical and should only be tem-
porary. In the event that an odor does occur, it
should subside and dissipate within 12 hours of
full operation. If this odor persists longer than 48
hours, you should unplug the PCO and contact
your Lennox authorized dealer.

Ultraviolet (UV-A) radiation risk.

Prolonged exposure may cause skin or eye damage.

Avoid prolonged (weeks) exposure to skin or eyes.

CAUTION

Clean lamps prior to installation using a cotton
cloth to remove dirt and fingerprints.

Failure to clean lamps could reduce the system's
efficiency.

NOTICE

Lamps contain Mercury.

Ingestion or contact with mercury or mercury vapor
is hazardous to your health.

Take care when handling lamps. If lamp breaks,
avoid contact with mercury.

CAUTION

The PCO-12C/20C has three components that will
require maintenance: MERV 9 pleated filter, metal
insert, and UVA lamps.(For replacement part num-
bers refer to Replacement Parts section in these
instructions. PCO-12C/20C performance will be
dramatically reduced if the required maintenance
is not performed on these three components.)

Summary of Contents for PureAir PCO-12C-2

Page 1: ...atalyst combines with water vapor in the air to form hydroxyl radicals that destroy a percentage of the remaining odors and chemicals In laboratory field tests we found greater than TVOC within 24 hours of initial installation and operation of the PureAir air purification system When the system is first started it may take up to 48 hours to reduce the airborne chemicals that have built up in your ...

Page 2: ...0 F 140 F 18 C 60 C Outside of duct 10 60 relative humidity PCO has optimal per formance at 50 relative humidity PLEATED FILTER EFFICIENCY Minimum Efficiency Rating Value MERV 9 Tested to ASHRAE Standard 52 2 Dimensions Specifications LISTINGS ETL Safety Listing Report J99 9379 001 Conforms to UL STD 1598 Certified to CSA STD C22 2 NO 250 0 Specifications subject to change without notice 11 5 8 19...

Page 3: ...dous to your health Take care when handling lamps If lamp is broken avoid contact with mercury CAUTION Sharp edges hazard Equipment sharp edges can cause injuries Use protective gloves when grasping equipment edges CAUTION Fig 2 Verify proper installation of lamps CHECKING THE LAMPS Fig 2 Lamps are factory installed as shown below Make sure that the lamps have not become disengaged during shipping...

Page 4: ...handler s should be sealed to prevent contamination from unconditioned spaces such as basements garages or attics Optionally the cabinet can be strap mounted from the ceiling When drilling screw holes in the cabinet for straps be sure to locate them where they do not inter fere with the insertion of the PCO 12C 20C assembly Airflow direction INSTALLING THE CABINET Cont d INSTALLING THE ASSEMBLY Fi...

Page 5: ...d Use Lennox blower relay part number 45H03 Lennox utilizing the Lennox Surelight heating control do not require the use of an additional blower relay Operation WIRING INSTRUCTIONS See wiring diagrams The PCO 12C 20C must be wired in accordance with national and local codes IMPORTANT To ensure UVA lamps life power MUST remain on to PCO 12C 20C at all times Do not interlock with air handler blower ...

Page 6: ...tall access door 5 Reconnect power cord 6 Verify that the lamps are illuminated METAL INSERT LAMP REPLACEMENT Cont d 6 Install new metal insert 7 Slide assembly back into cabinet and install access door 8 Reconnect power cord 9 Verify that the lamps are illuminated Note DO NOT WASH metal insert Washing will destroy the titanium dioxide catalyst that coats the insert surface Note If the system has ...

Page 7: ...8 49M48 Contact your local Lennox dealer to order replacement parts For the Lennox dealer nearest you dial 1 800 9 LENNOX Visit us at http www Lennox com 7 LAMP DISPOSAL Hg LAMP CONTAINS MERCURY Manage in accord with disposal laws Refer to www lamprecycle org or call 1 800 9 LENNOX LAMP CHECKOUT Does not illuminate 1 Check power cord for 120V power 2 Unplug power cord and remove access door 3 Slid...

Page 8: ...ns bulbs and ballast Replace any burned out or damaged components and plug unit in Are Lamps Lit Yes No No Are Lamps Lit Are Lamps Lit Did Lamps Light Check power supply Breakers Plug Electrical wiring Repair electrical and plug unit in No Yes Continue with maintenance per unit instruction manual Yes Continue with maintenance per unit instruction manual Replace Assembly End End End End Unplug PCO ...

Reviews: