TERMINAL-THERMOSTAT INSTALLATION

This unit is valid for operating as a cold only or heat pump

application. The unit should be configured prior to making the

electrical connections, by setting  the configuration switch as

follows:

Your new LENNOX Thermostat has been designed to provide accurate control and display of room temperature. In

addition, it will also display all relevant information pertaining to your system.

The  clearly  marked  buttons  and  informative  display  make  it  extremely  easy  to  understand  and  simple  to  use.

Please take a few moments to read the brief instructions and familiarise yourself with the various functions in order to obtain

maximum benefit from this truly unique electronic control.

This electronic control is organised into two integrated systems: a terminal, installed in the room, and a power board for managing

the actuators in the electrical panel. The terminal is connected to the power board using a four-lead cable, thus greatly simplifying

installation, with shield cable (supplied with the unit).

TERMINAL INSTALLATION

For correct installation the following warnings must be heeded:

• Always disconnect the power supply before performing any operations on the board during assembly, maintenance or

replacement.

• The terminal should be fastened to the wall vertically, allowing for air to circulate through the instrument's vent-holes, in order

to detect the correct ambient temperature

• Avoid places where the measurement of the ambient temperature by the internal sensor may be altered, such as outside walls,

near doors leading outside, in direct sunlight, etc.

The installation procedure is as following:

1º To detach the front panel of the terminal from the rear shell,

insert a flat-head screwdriver in the slot in the centre of the bottom

of the box and release the locking flap.

2º Raise the front panel using a “hinge” movement, using the

upper edge of the instrument as the pivot and raising  the lower

edge.

3º To fasten the rear part of the box to the wall, use  the mounting

holes on the shell.

Cable supplied with

the  unit  Maximum

length  allowed  is

15m

Power board

UNIT

4º  Connect  the  cables  to  the

terminals on the electrical box, as

indicated  in  electrical  diagram.

5º Finally, close the instrument, moving the front panel onto the rear shell with a “hinge” movement, in the opposite way as used

for opening. First the long side of the front panel near the display is snapped onto the rear shell, then the opposite side, being

careful that the terminal pins slide into their corresponding female terminals.

Sub-base

Terminal-Thermostat

INSTALLATION GUIDE FOR CONTROL CABLE (TO AVOID INTERFERENCES):

• Use the screened 15 m cable supplied with terminal (3 wires + screen).

• Wire the cable separated from electrical power wiring by a physical distance of 500 mm.

• Wire the cable separated from halogen lamps/fluorescent tube lighting... by a physical distance of 500 mm.

• Wire the cable separated from radio frequency sources such as radio transmitter... at least 500 mm.

NEVER WIND THE REMAINING CABLE AROUND, CUT THE CABLE BY THE TERMINAL END.

CONTENTS

• TERMINAL-THERMOSTAT INSTALLATION AND UNIT CONFIGURATION

• USER INTERFACE DESCRIPTION

• SELECTING UNIT OPERATING MODE AND SET-POINT

• PROGRAMMING ADJUSTMENT

• ALARM CODES

• UNIT PROTECTION DEVICES

PAGE

1

2

3-4

5

6

6

ON / 

OFF

ON / O

FF

1

2

ON / OFF

KEY LOCK

AUTO

AUTO

DRY

COOL HEAT FAN

COOL

TEMP.

HEAT

TEMP.

ROOM

TEMP.

TIMER ACTIVE

SET TIMER

SET CLOCK

MON  TUE WED THU FRI SAT SUN

SLEEP
SWING

SLEEP

MODE

SWING

ON TIMER

OFF TIMER

HOLD

DAY

HOUR

MINUTE

CLOCK

SET TEMP

FAN

IMPORTANT

Prior of making the electrical connections, set the switch for heat pump unit or for cooling

only unit.

NOT USED FOR CASSETTE UNITS. (See documentation for the unit)

HEAT PUMP

J_MODE

COOLING ONLY

(factory setting)

P.C.B.

J_MODE

J_MODE

Summary of Contents for OLT-1X

Page 1: ...Providing indoor climate comfort OLT 1X MUL30E 0303 09 2006 User manual Control...

Page 2: ...f the box and release the locking flap 2 Raise the front panel using a hinge movement using the upper edge of the instrument as the pivot and raising the lower edge 3 To fasten the rear part of the bo...

Page 3: ...g Indicates we are setting the clock Temperature button Pressing them the display shows the set point or the room temperature and with them we can select the desired temperature set point C or F Displ...

Page 4: ...unit operating mode and choose the one desired COOL The unit is working on cooling mode when compressor is working symbol will appear on the display HEAT The unit is working on heating mode when comp...

Page 5: ...s will flash on the screen ON TIMER SET TIMER With the button select the day of the week that you wish to program Any previous settings will be displayed DAY Push the button to finish the programming...

Page 6: ...et Point 1 C Set Point 2 C C MON TUE WED THU FRI SAT SUN Press button once to set the clock mode the indication will appear on the display blinking Press button repeatedly scrolls through the followin...

Page 7: ...irst time To reset for second time press button ON OFF until alarm disappears If the alarm shows up again check Connections of indoor coil temperature probe Indoor unit works properly Clean air filter...

Page 8: ...303 09 2006 BELGIUM LUXEMBOURG CZECH REPUBLIC FRANCE GERMANY NETHERLANDS POLAND PORTUGAL RUSSIA SLOVAKIA SPAIN UKRAINE UNITED KINGDOM AND IRELAND OTHER COUNTRIES Due to Lennox s ongoing commitment to...

Reviews: