Application Guide /NEOSYS-AGU-1801-E
*except in case of main power connection option
OPTIONS AND ACCESSORIES
OPTIONS
DESCRIPTION
ADVANTAGES
MODELS
Soft starter
Electronic soft starter
fi
tted into the electrical
cabinet
Start-up current reduced by 15 % up
to 30 %.
Power Factor correction
Capacitors
fi
tted into the unit
Cos phi correction up to 0.95
to reduce current and energy
consumption.
Electric meter
Active energy total counter, power factor,
operating time counter, max. active power
demand, ModBus.
This device allows monitoring of the
unit electric power consumption on
the unit and from a BMS
Single main power
connection
Electrical cabinet equipped with one single
point of connection and power cut-off for the
complete unit.
Allow easy electrical connection
with one single cable instead of two
cables
BE60 extension board for
additional inputs/outputs
Electronic extension board with additional
analog inputs (4), digital inputs (4) and digital
outputs (4). See control manual.
Relay card for remote control and
alarm report using dry contacts, 24
Vac or 4-20 mA signals.
Modbus communication
interface
Communication card using ModBus/JBus
protocol with RS485 or TCP/IP connection.
Communication interface with a
building management system.
LonWorks® communication
interface
Communication card using LonTalk® protocol
with FTT-10A connection.
Communication interface with a
building management system.
BACnet® communication
interface
Communication card using Bacnet® protocol
with RS485 or TCP/IP connection.
Communication interface with a
building management system.
ACCESSORIES
DESCRIPTION
ADVANTAGES
MODELS
Water
fi
lter
1000 microns water Y
fi
lter delivered with
piping and
fl
ange connections.
This protection must be
fi
tted in
the customer water supply piping
to protect the evaporator from any
possible impurities.
Flange connection
Two connections sleeves with victaulic groove
and
fl
ange on opposite side.
Allow easy connection with
fl
anges
on customer side.
Anti-vibration mounts
Rubber anti-vibration mounts to be mounted
under the unit.
Reduction of the transmission of
vibration to the ground and the
general level.
DC60 remote comfort
display
Customer display located at 600 meters
maximum from the unit.
Remote customer parameter reading
and modi
fi
cation.
DS60 service display
Plug and play display delivered with 1 meter
cable and connector for quick connection on
Climatic controller.
Display for service technicians only.
Adalink™ supervision
Electronic board with RS485 cables, RJ11
phone cable, Ethernet cable and power supply
cable.
Remote supervision of the unit via an
intuitive web page.