background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Main Gas 

Shut-Off Valve

LENNOX HEARTH PRODUCTS • MERIT

®

 SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION

Gas Controls/Control Compartment 

Access

The gas controls can be found behind the control 

compartment access door. 

Removing Control Compartment Door

Open the panel by grasping the control 

compartment door on both sides and gently 

pulling the top away from the fireplace to 

disengage the magnetic fasteners. The door is 

hinged at the bottom. If greater access to the 

control compartment is required, slide the door, 

first to one side and then the other, so the tabs 

clear both of the locating holes.

OPERATION AND CARE OF YOUR APPLIANCE

       WARNING 

Young children should be carefully supervised when they are in the 

same room as the appliance. Toddlers, young children and others 

may be susceptible to accidental contact burns. A physical barrier is 

recommended if there are at risk individuals in the house. To restrict 

access to a fireplace or stove, install an adjustable safety gate to keep 

toddlers, young children and other at risk individuals out of the room 

and away from hot surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou-

vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants 

ou les adultes peuvent subir des brûlures s’ils viennent en contact avec 

la surface chaude. Il est recommandé d’installer une barrière physique 

si des personnes à risques habitent la maison. Pour empêcher l’accès à 

un foyer ou à un poêle, installez une barrière de sécurité; cette mesure 

empêchera les tout petits, les jeunes enfants et toute autre personne à 

risque d’avoir accès à la pièce et aux surfaces chaudes.

Figure 1 - Control Compartment

Gas Flex Line

3 Inch

Pipe Nipple

Valve

Piezo

(Millivolt only)

Spring Door

Latch

Lower Control

Compartment

Rocker Switch (Millivolt only) /

Pilot Control Switch (Electronic only)

On millivolt systems, the piezo igniter, HI/LO 

flame  adjustment  knob,  and  pilot  and  main 

gas  OFF/ON  control  knob  are  located  below 

the glass panel enclosure. The gas valve for 

electronic systems is also located below the 

glass enclosure panel (see 

Figure 1

)

.

Reinstalling Control Compartment Door

If necessary, reinstall the door by inserting 

the tabs on each side of the door into the 

corresponding holes in the control compartment 

opening, one side first then the other. Swing the 

door gently up and fasten it by pushing it in until 

the magnetic latches catch and lock it in place.

The standard controls for appliance operation 

are located behind the panel below the appliance 

front glass enclosure panel (

Figure 1

). Optional 

control switches are also available (see 

Page 

17 

Remote Wall Switch, Remote Control or 

Unit Mounted Rocker Switch).

Operation of millivolt and electronic gas con-

trol systems are different. Before lighting and 

operating your appliance determine if you have 

a millivolt or electronic appliance. Familiarize 

yourself with the gas control valve that your 

appliance uses. Refer to 

Figure 1 

for access to 

the gas control valve. 

  Millivolt Appliances 

- Appliances with 

Millivolt systems will be fitted with the gas 

control valve shown in 

Figure 3. 

 

Electronic Appliances

 - Appliances with 

electronic systems will be fitted with the 

electronic valve shown in 

Figure 4. 

Millivolt Appliances - 

To light millivolt ap-

pliances refer to 

Figure 1

. Detailed lighting 

instructions are found on 

Page 20

Millivolt 

appliance lighting instructions may also be 

found on the pull out lighting instruction labels 

attached to the gas control valve

.

Once the pilot is lit, the main burner may be 

turned ON and OFF using a wall switch, remote 

control or optional on unit rocker switch (FRS). 

To operate: Toggle the switch between its ON 

and OFF positions.

If your millivolt appliance is equipped with an 

optional remote switch kit (wall switch, remote 

control, or rocker switch) and the pilot is lit, the 

appliance main burner may be turned on and 

off using the optional switch.

NOTE:

  To prevent excessive resistance in 

burner circuit (which can cause burner opera-

tion problems), only one burner control switch 

should be wired to valve. 

Figure 2 - Removing Control 

Compartment Door

Control 

Compartment 

Door Tab

Summary of Contents for MLDVTCD-35NE-2

Page 1: ...OW CHILDREN TO TOUCH GLASS UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D Y TOUCHER NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO Do not store or use gasoline or other flammable vapors and liquids in the vicinity of thi...

Page 2: ...ation Notices 6 Warranty Information 6 General Information 7 Operation Care of Your Appliance 8 Gas Controls Access 8 Variable Flame Adjustment 9 Maintenance 10 Front Glass Enclosure Panel Removal and Installation 11 Install Contemporary Media 12 Burner Flame Appearance Sooting 14 Burner Flame Adjustments 15 Millivolt Appliance Checkout 15 Electronic Appliance Checkout 15 Ordering Replacement Part...

Page 3: ...levées voir page 5 Lisez la section Informations importantes relatives à la sécurité page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un Lennox SAFETY GUARD GRATIS para su chimenea Sig...

Page 4: ...les adultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces ...

Page 5: ... interruptor opera la chimenea encendiéndola y apagándola Limpie bien la placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura A Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el polvo y ...

Page 6: ...nge to this appliance and or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similartothefluwithheadaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas suppl...

Page 7: ... are provided on the front of the millivolt gas control valve identi fied IN for the inlet and OUT for the manifold side see Figure 3 and Figure 4 on Page 9 IMPORTANT NOTE A white film may develop on the glass enclosure panel during the first few fires as part of the burn in process The first few times you use the fireplace clean the glass after each use AFTER THE GLASS HAS COMPLETELY COOLED other...

Page 8: ...ustment knob and pilot and main gas OFF ON control knob are located below the glass panel enclosure The gas valve for electronic systems is also located below the glass enclosure panel see Figure 1 Reinstalling Control Compartment Door If necessary reinstall the door by inserting the tabs on each side of the door into the correspondingholesinthecontrolcompartment opening one side first then the ot...

Page 9: ... may have a CPI switch located in the lower control compartment Figure 1 This switch allows the pilot to be switched from intermittent mode pilot is extinguished when the fireplace is OFF to continuous mode pilot stays on when fireplace is OFF In periods of extreme cold you may notice condensation on the glass door when the fireplace is OFF and the pilot is in intermittent mode Also with the pilot...

Page 10: ... before initial use and at least annually by a qualified service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once if any abnormal condition is observed If the venting system is disassembled for any reason a qualified service technic...

Page 11: ...tiré pour permettre l entretien de l appareil doit être remis en place avant de mettre l appareil en marche WARNING Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass Handlethisglasswithextreme care Glass is susceptible to damage Do not scratch or handleroughlywhilereinstall ing the glass door frame The glass door s of this appli ance must only be replaced a...

Page 12: ...el and lower it into place while standing it upright and press ing it down over the knife edge at the rear of the sub floor The sub floor knife edge will cut into the refractory panel Repeat the same procedure for the Zen Garden right side panel 5 Re install the lintel and screws Catalog Number Model Number Description H7536 MTRS Tumbled River Stone H7537 MCCG OB Contemporary Glass Obsidian Black ...

Page 13: ... Obsidian Contemporary Glass Tumbled River Stone Burner Outlet Tumbled River Stone NOTE River Stone And Beach Sand May Be Used Together Zen Garden Firebox Liner Side Panels Burner Outlet Left Zen Garden Panel Right Zen Garden Panel Diamond White Contemporary Glass Crushed Glass and Sand Burner Outlet Contemporary Beach Sand NOTE Beach Sand And River Stone May Be Used Together Figure 6 MLDVTCD 35 F...

Page 14: ... with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the contemporary media positioning to ensure that the flames are not impinging on any of the contemporary media If the contemporary media is properly positioned and a sooting condition still exists then the air shutt...

Page 15: ...teadjustmentrodandadjustairshutter to the standard setting as shown in Figure 8 adjustment rod is located in the lower control compartment NOTE Rotating the adjustment rod down to decrease air and up to increase air 2 Lightappliance followlightingprocedureon lighting label in control compartment or see the lighting instructions Pages 20 23 in this manual 3 Allowtheburnertooperateforatleast15min ut...

Page 16: ... number of your nearest LHP dealer who will answer your questions or address your concerns LENNOX hEARTH pRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www LennoxHearthProducts com 1 800 655 2008 If you encounter any problems or have any questions concerning the installation or ap plication of this system please contact your dealer or distributor PRODUCT REFERENCE INFORMATION We recommen...

Page 17: ...3 hr Countdown Timer modes LCD display Displays room temp in ºF or ºC Flame icon and low battery indicator Includes batteries Wall clip included Receiver may be wall mounted or placed in the control compartment Includes white face plate Flame icon Low battery indicator Batteries included G Fire Remote Simple On Off Cat No Model No Description H8840 KIT RC G FIRE Remote Control Cost Effective Solut...

Page 18: ...Description H5820 4 5HTSK Termination Shroud 87L02 SV4 5HGS Termination Guard Deluxe 17M52 SV4 5HGS 1 Termination Guard Square Square Termination Guard fits 94L10 and H1968 ref Instruction P N 750109M Deluxe Termination Guard fits 94L10 and H1968 ref Instruction P N 750055M Termination Guard Kits Theventterminationguardsmaybeusedtocoverthe vent termination on the exterior of the home to mini mize ...

Page 19: ... Facade Base Facade Frame and Facade Trim Cat No ModelNo Description H7732 CDFBBK 35 Facade Base Black H7733 CDFBSS 35 Facade Base Stainless H7730 CDFFBK 35 Facade Frame Black H7731 CDFFSS 35 Facade Frame Stainless H7727 CDTKBK 35 Facade Trim Black H7728 CDTKSS 35 Facade Trim Stainless H7729 CDTKBR 35 Facade Trim Polished Brass LENNOX HEARTH PRODUCTS MERIT SERIES DIRECT VENT CONTEMPORARY DESIGN GA...

Page 20: ...goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob counterclockwise to ON 11 Close control compartment 1...

Page 21: ...eilleuse Relâchez le bouton et il sortira subitement La veilleuse devrait rester allumée Si elle s éteint répétez les étapes 5 à 8 inclusivement Si la manette ne se soulève pas d elle même lorsqu on la relâche arrêter et appeler immédiatement un technicien qualifié ou le fournisseur de gaz Si la veilleuse ne reste pas allumée après plusieurs tentatives réglez la manette d admission du gaz à la pos...

Page 22: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed NOTE The control may have a battery backup remo...

Page 23: ...ntrôleur peut avoir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du récepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF pour sélectionner ON 10 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 11 Si l appareil ne se met pas en marche suivez les instructions intitulées Comm...

Page 24: ...be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Batteries Homeowner Qualified Service Technician For electronic valve m...

Page 25: ...h is ON NOTE If an optional remote switch is used for burner operation and if a unit mounted control switch is installed it must be in the OFF position A Wall switch or wires defective Check wall switch and wires for proper connections Jumper wire across terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes ...

Page 26: ...he gas supply and gas shutoff valves call a service technician if required C Pilot flame is not engulfing the sensor Call a service technician D Obstructed vent system Call a service technician 4 Soot is present on the glass and panels A Initial fireplace operation A white film may develop on the glass during the first few fires as part of the burn in process The first few times you use the firepl...

Page 27: ...L10 1 7 Bag of Contemporary Media Tumbled River Stone H7536 1 Bag of Contemporary Media White Beach Sand H7538 1 Bag of Contemporary Media Obsidian Black Glass H7537 1 Bag of Contemporary Media Diamond White Glass H7578 1 Bag of Contemporary Media Deep Sea Blue Glass H7579 1 8 Orifice Holder H7257 1 9 Gas Line Flexible Connector 93L32 1 10 Sub Floor Front Panel H7747 1 11 Sub Floor H7677 1 12 Porc...

Page 28: ...ns prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc and are used with permission Printed in U S A 2013 Lennox Hearth Products LLC P N 506017 08 Rev A 04 2013 14 13 LENNOX ...

Reviews: