Page 4

this appliance is maintained. Proper maintenance is criti-
cal for your safety and the satisfactory operation of the
product. 

Lennox strongly recommends annual in-

spection and maintenance of this appliance.

 Contact

your Lennox dealer for an inspection by a licensed profes-
sional  service technician (or equivalent).

DANGER

Danger of explosion.

There are circumstances in which odorant used with
LP/propane gas can lose its scent.  In case of a leak,
LP/propane gas will settle close to the floor and may
be difficult to smell. An LP/propane leak detector
should be installed in all LP applications.

Do not attempt to bleed the gas lines of air. Call your
local gas provider.

Start−Up & Operation Information

WARNING

If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or death.

BEFORE PLACING THE UNIT INTO OPERATION,

 smell

all around the appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than air and will
settle on the floor.

The gas valve on the ML180UHE will be equipped with a
gas control switch. Use only your hand to move the
switch. Never use tools. If the switch will not move by
hand, do not try to repair it. Call a licensed professional
service technician (or equivalent). Force or attempted re-
pair may result in a fire or explosion.

Placing the ML180UHE furnace into operation:

ML180UHE units are equipped with an ignition system.
Do not attempt to manually light burners on this furnace.
Each time the thermostat calls for heat, the burners will
automatically light. The ignitor does not get hot when
there is no call for heat on units with this ignition system.

Operating the Gas Valve (Figure 2)

 1 −

STOP

! Read the safety information at the beginning of

this section.

 2 − Set the thermostat to the lowest setting.
 3 − Turn off all electrical power to the unit.
 4 − This furnace is equipped with an ignition device which

automatically lights the burners. Do 

not

 try to light the

burners by hand.

 5 − Remove the upper access panel.
 6 − Move switch on gas valve to 

OFF

. See figure 2.

 7 − Wait five minutes to clear out any gas. If you then smell

gas, 

STOP

! Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s instruc-
tions. If you do not smell gas go to next step.

 8 − Move switch on gas valve to 

ON

. See figure 2.

FIGURE 2

GAS VALVE SHOWN IN ON POSITION

MANIFOLD

PRESSURE

OUTLET

PORT

INLET

PRESSURE

PORT

MANIFOLD

PRESSURE

ADJUSTMENT

SCREW

 9 − Replace the upper access panel.

10 − Turn on all electrical power to to the unit.

11 − Set the thermostat to desired setting.

NOTE − When unit is initially started, steps 1 through 11
may need to be repeated to purge air from gas line.

12 − If the appliance will not operate, follow the section

Turning Off Gas to the Unit" and call your licensed
professional service technician (or equivalent).

Turning Off Gas to the Unit

 1 − Set the thermostat to the lowest setting.

 2 − Turn off all electrical power to the unit if service is to be

performed.

 3 − Remove the upper access panel.

 4 − Move switch on gas valve 

OFF

.

 5 − Replace the upper access panel.

Summary of Contents for ML180DFE SERIES

Page 1: ...by a qualified installer service agency or the gas supplier D Do not try to light any appliance D Do not touch any electrical switch do not use any phone in your building D Immediately call your gas s...

Page 2: ...the equipment user Notice to Homeowner This furnace is equipped with safety devices that protect you and your property If one or more of these devices is activated furnace operation will stop If your...

Page 3: ...lear ances surrounding the furnace 3 DO NOT store chlorine or fluorine products near unit or introduce these products into the combustion air These products can cause furnace corrosion 4 DO NOT draw r...

Page 4: ...Do not attempt to manually light burners on this furnace Each time the thermostat calls for heat the burners will automatically light The ignitor does not get hot when there is no call for heat on uni...

Page 5: ...quivalent must annually inspect this furnace and its vent system Annually before heating season inspect furnace venting system vent cap heat exchanger and burners for corro sion deterioration or depos...

Page 6: ...f you suffer from flu like symp toms that are exaggerated at home but seem to sub side while you are away from the house exposure to carbon monoxide could be the cause Your vigilance may pay off in ea...

Page 7: ...off plate WARNING Product contains fiberglass wool Disturbing the insulation in this product during installation maintenance or repair will expose you to fiberglass wool Breathing this may cause lung...

Reviews: