Model
LM012CI-100V232-1X/
LM012CO-100V232-1X
LM012HI-100V232-1X/
LM012HO-100V232-1X
Product Code
Y6687/Y6688
Y6697/Y6698
Power
Supply
Rated Voltage
V~
115
115
Rated Frequency
Hz
60
60
Phases
1
1
Power Supply Mode
Indoor
Indoor
Cooling Capacity
W
3370
3282
Heating Capacity
W
/
3517
Cooling Power Input
W
1190
1180
Heating Power Input
W
/
1050
Cooling Power Current
A
10.35
10.47
Heating Power Current
A
/
9.31
Rated Input
W
1650
1700
Rated Current
A
14.35
16.50
Air Flow Volume(SH/H/M/L/SL)
m
3
/h
550/460/380/300/-
600/470/380/320/-
Dehumidifying Volume
L/h
1
1
EER
W/W
3
3
COP
W/W
/
3
SEER
W/W
/
/
HSPF
W/W
/
/
Application Area
m
2
16-24
15-22
Indoor Unit
Model of indoor unit
LM012CI-100V232-1X
LM012HI-100V232-1X
Indoor Unit Product Code
Y6687
Y6697
Fan Type
Cross-flow
Cross-flow
Diameter Length(DXL)
mm
Φ98X580
Φ98X580
Fan Motor Cooling Speed(SH/H/M/L/SL)
r/min
1450/1200/1050/800
1450/1200/1050/800/-
Fan Motor Heating Speed(SH/H/M/L/SL)
r/min
/
1350/1200/1050/900/-
Output of Fan Motor
W
20
20
Fan Motor RLA
A
0.17
0.4
Fan Motor Capacitor
μF
4
4
Input of Heater
W
/
/
Evaporator Form
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Pipe Diameter
mm
Ф5
Φ5
Row-fin Gap
mm
2-1.4
2-1.4
Coil Length (LXDXW)
mm
584X22.8X266.7
584X22.8X266.7
Swing Motor Model
MP24AA
MP24AA
Output of Swing Motor
W
1.5
1.5
Fuse
A
3.15
3.15
Sound Pressure Level (SH/H/M/L/SL)
dB (A)
42/38/34/29/-
43/38/34/29/-
Sound Power Level (SH/H/M/L/SL)
dB (A)
52/48/44/39/-
53/48/44/39/-
Dimension (WXHXD)
mm
790X200X275
790X200X275
Dimension of Carton Box (LXWXH)
mm
850X264X339
850X339X262
Dimension of Package (LXWXH)
mm
853X267X354
853X342X277
Net Weight
kg
9
9.5
Gross Weight
kg
11
11.5
Summary of Contents for LM012CI-100V232-1X
Page 16: ...13 Technical Information Service Manual AUTO COOL DRY FAN HEAT OFF...
Page 17: ...14 Technical Information Service Manual battery Cover of battery box remove reinstall...
Page 18: ...15 Technical Information Service Manual...
Page 43: ...40 Installation and Maintenance Service Manual LM012CO 100V232 1X 10 2 Outdoor Unit...
Page 45: ...42 Installation and Maintenance Service Manual LM012HO 100V232 1X...