INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR PureAir™ MODEL PCO-20P-2

Shipping and Packing List

Unique Supplies 

(Provided by installer.)

General

Package 1 of 1 contains:

1 - PureAir™ air purification system:
 

1 - Metal rack, including cap and metal air strip seal

   1 - One piece slide-in assembly

 

(Metal Frame and 

ballasts, with associated wiring.)

   1 - MERV 16, 4" pleated filter
   6 - Installed UVA lamps
   1 - Separately wrapped titanium dioxide insert

3 - Self-drilling serrated 5/16" hex head screws for 

mounting transformer/fuse assembly. (1 extra)

8 - 5/16" hex slotted head screws for mounting PCO 

rack to ResPak unit. (2 extra)

1 - Transformer/fuse assembly 
1 - Installation and maintenance instructions
1 - Homeowners IAQ Guide
1 - Warranty certificate
1 - Registration card

• Cotton gloves and cloth (to remove finger prints 

from lamps.)

• Sealant: Aluminum foil duct tape or water based 

mastic. (NOT silicone)

The PureAir™ air purification system helps to sig-
nificantly reduce levels of airborne volatile organic 
compounds, cooking odors, common household 
odors, airborne dust particles, mold spores, and 
pollen in residential spaces. The PureAir™ air puri-
fication system includes a MERV 16 pleated filter, 
UVA lamps, and an insert that is coated with a titani-
um dioxide catalyst. As air enters the system, more 
than 95% of airborne particles and bioaerosols, 
such as mold and bacteria, ranging in size down 
to .3 microns, are captured by the pleated filter. 
Odors and chemicals continue through the system. 
The UVA lamps activate the catalyst on the insert. 
The catalyst combines with water vapor in the air to 
form hydroxyl radicals that destroy a percentage of 
the remaining odors and chemicals.
In laboratory & field tests, we found greater than 
50% reduction in Total Volatile Organic Compounds 
(TVOC) in homes within 24 hours of initial instal-
lation and operation of the PureAir™ air purifica-
tion system. When the system is first started, it 
may take up to 48 hours to reduce the airborne 
chemicals that have built up in your home over a 
long period of time. After that period, there will be 
a balance between chemicals emitted inside your 
home and chemicals removed by your PureAir™ 
air purification system. Please refer to the included 
Homeowners IAQ guide for other measures to 
improve indoor air quality.

The PureAir™ air purification system is NOT intended to be used for 

removal of active mold growth or continuous sources or high levels 

of chemicals in the air. For existing mold growth, the mold must be 

appropriately removed PRIOR to installation of your PureAir™ air 

purification system.

213033-00 Rev. 2B 9/07

©2007 Lennox Industries, Inc.

Dallas, Texas USA

Possible odor emissions.

Odors may be present temporarily from chemical inter-

mediates after initial start-up, painting, cleaning, remod-

eling, hobby activities, or similar activities, or after lamp 

replacement.
Some  occupants  may  notice  irritation  or  discomfort 

during this period.
If  irritation  or  discomfort  persists  longer  than  48 

hours, contact your Lennox dealer.

NOTICE

Risk of property damage, injury, or death.

Installation,  adjustments,  alterations,  service  and 
maintenance must be performed by a qualified ser-
vice technician.

WARNING

Electric shock hazard.

Can cause injury or death.
Disconnect  all  remote  electrical 
power supplies before servicing.
Access panels must be in place dur-
ing the appliance operation.

WARNING

Summary of Contents for Healthy Climate PureAir PCO-20P-2

Page 1: ...sert The catalyst combines with water vapor in the air to form hydroxyl radicals that destroy a percentage of the remaining odors and chemicals In laboratory field tests we found greater than 50 reduc...

Page 2: ...V Model PCO 20P 120V 1 2 Amps 60Hz POWER CONSUMPTION Model PCO 20P 144 Watts OPERATING ENVIRONMENT 41 F 140 F 5 C 60 C Outside of duct 10 60 relative humidity PCO has optimal per formance at 50 relati...

Page 3: ...proper installation can damage HVAC system PureAir system or other equipment and may void warranty NOTICE Upper Return Cover Filter Panel Blower Panel Electrical Panel Fig 4 Remove return cover and fi...

Page 4: ...ction 1 Remove filter access door For installation from the outside i e before ductwork is installed 2 Slide rack into unit and align rack with Return Air RA holes in package unit The rack should be c...

Page 5: ...HE ASSEMBLY Fig 8 Oil on metal ducts can cause odors Wash all new transitions and duct surfaces with mild soap and water to remove oils prior to installation NOTICE Ultraviolet UV A radiation risk Pro...

Page 6: ...in situ ations with high dust dirt loads or when operating in continuous fan mode Maintenance INSERT AND LAMP REPLACEMENT Replace insert and lamps every 24 months Replace insert more frequently if yo...

Page 7: ...Lamps contain Mercury Ingestion or contact with mercury or mercury vapor is hazardous to your health Take care when handling lamps If lamp breaks avoid contact with mercury CAUTION PROPER CLEAN UP TEC...

Page 8: ...5X66 5 MERV 16 pleated filter X6669 6 Surge Protector Module 79M75 7 Ballast 69M77 3 8 Electrical Socket 75X77 9 Transformer 230V 208V to 115V X5404 10 Fuse Holder X5402 2 11 Fuse 2 Amp X5401 2 12 Tra...

Page 9: ...d components and plug unit in Are Lamps Lit Yes No No Are Lamps Lit Are Lamps Lit Did Lamps Light No Yes Continue with maintenance per unit instruction manual Yes Continue with maintenance per unit in...

Reviews: