background image

XP16 − 2 to 5 Ton Heat Pump

 / Page 9

ARI RATINGS 

ARI Standard 210/240 Ratings

Capacity − Btuh

Efficiency

Total Watts

COP

I d

U it M d l N

Expansion

Cooling

High

Temp

Low

Temp

HSPF

Cool

High Low High Low

Indoor Unit Model No.

Expansion
Device

Cooling Temp.

Heating

Temp.

Heating SEER EER

IV

V

Cool

High

Heat

Low

Heat

High

Heat

Low

Heat

XP16−024

2 TON

Air Handlers

Air Handlers

23,800 21,800 13,000 15.70 11.70 8.00 6.70 2025 1810 1600 3.52 2.38

CBX32MV−018/024 (Multi−Position)

Factory TXV

23,400 22,000 13,300 14.20 11.00 7.70 6.70 2110 1910 1695 3.38 2.30

CBX32M−018/024 (Multi−Position)

Factory TXV

24,000 22,200 13,400 15.00 11.20 7.70 6.70 2130 1885 1685 3.46 2.32 CBX26UH−018 (Up−Flow / Horizontal)

Factory TXV

24,200 21,600 12,900 16.00 12.00 8.20 7.00 1970 1725 1525 3.66 2.48

4,5 

CBX32MV−024/030 (Multi−Position)

Factory TXV

24,200 21,600 12,800 16.00 12.20 8.20 7.00 1960 1715 1515 3.70 2.48

CBX27UH−024 (Up−Flow/Horizontal)

Factory TXV

24,200 22,000 13,300 15.00 11.50 8.00 6.70 2095 1845 1645 3.50 2.36 CBX26UH−024 (Up−Flow / Horizontal)

Factory TXV

24,400 21,600 12,800 17.00 12.50 8.50 7.20 1940 1680 1490 3.76 2.52

CBX27UH−030 (Up−Flow/Horizontal)

Factory TXV

24,200 22,200 13,400 15.20 11.50 8.00 7.00 2105 1820 1635 3.58 2.40

CBX32M−030 (Multi−Position)

Factory TXV

24,800 22,000 13,000 17.00 12.20 8.50 7.20 1995 1685 1515 3.82 2.52

CBX32MV−036 (Multi−Position)

Factory TXV

Up−Flow Indoor Coils

Up−Flow Coils

23,600 22,200 13,400 14.00 11.00 7.70 6.70 2145 1910 1700 3.40 2.30

CX34−38A/B−6F

Factory TXV

Up−Flow Indoor Coils + Furnaces

Up−Flow Coils + Furnaces

23,800 21,400 12,700 16.00 12.00 7.70 6.70 1975 1800 1585 3.48 2.34 CX34−36C−6F

G61MPV−36C−090

Factory TXV

23,800 21,400 12,700 16.00 12.00 7.70 6.70 1975 1800 1585 3.48 2.34 CX34−36C−6F

G71MPP−36C−090

Factory TXV

23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36A−6F

G60UHV−36A−070

Factory TXV

23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36B−6F

G61MPV−36B−070

Factory TXV

23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36B−6F

G71MPP−36B−070

Factory TXV

24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25A−6F

G60UHV−36A−070

Factory TXV

24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25B−6F

G61MPV−36B−070

Factory TXV

24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25B−6F

G71MPP−36B−070

Factory TXV

24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CX34−36B−6F

G60UHV−36B−090

Factory TXV

24,000 21,400 12,800 16.00 11.70 7.70 6.70 2010 1845 1625 3.40 2.30 CX34−25B−6F

G61MPV−36B−045

Factory TXV

24,000 21,600 12,900 16.00 11.70 7.70 6.70 2010 1815 1605 3.48 2.36 CX34−36B−6F

G61MPV−36B−045

Factory TXV

24,200 21,200 12,700 16.20 12.20 7.70 6.70 1970 1815 1595 3.42 2.34 CX34−25B−6F

G60UHV−36B−090

Factory TXV

24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31B−6F

G61MPV−36B−070

Factory TXV

24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31B−6F

G71MPP−36B−070

Factory TXV

24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31A−6F

G60UHV−36A−070

Factory TXV

24,400 21,400 12,800 16.20 12.00 7.70 6.70 2015 1845 1625 3.40 2.30 CX34−31B−6F

G61MPV−36B−045

Factory TXV

24,400 21,600 12,900 16.20 12.20 8.20 7.00 1980 1730 1525 3.66 2.48 CX34−38B−6F

G60UHV−36B−090

Factory TXV

24,400 21,800 13,000 16.00 12.00 8.20 7.00 2015 1765 1560 3.62 2.44 CX34−38B−6F

G61MPV−36B−045

Factory TXV

24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38A−6F

G60UHV−36A−070

Factory TXV

24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38B−6F

G61MPV−36B−070

Factory TXV

24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38B−6F

G71MPP−36B−070

Factory TXV

24,400 21,600 12,900 16.20 12.20 8.20 7.00 1980 1730 1525 3.66 2.48 CX34−38B−6F

G60UHV−36B−090

Factory TXV

24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38A−6F

G60UHV−36A−070

Factory TXV

24,600 21,200 12,700 16.50 12.20 7.70 6.70 1980 1815 1590 3.42 2.34 CX34−31B−6F

G60UHV−36B−090

Factory TXV

Down−Flow Indoor Coils

Down−Flow Coils

23,200 22,200 13,400 14.00 10.85 7.70 6.70 2135 1925 1705 3.38 2.30

CR33−24A/B−F

49L24

23,600 22,400 13,500 14.20 11.00 7.70 6.70 2135 1885 1685 3.48 2.34

CR33−30/36A/B/C−F

49L24

NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).

1

Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;

Cooling Ratings − 

95

_

F outdoor air temperature and 80

_

F db/67

_

F wb entering indoor coil air.

High Temperature Heating Ratings − 

47

_

F db/43

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

Low Temperature Heating Ratings − 

17

_

F db/15

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

2

Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).

3

Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (

58M81

) is recommend for field installation.

4

Blower control must be set for a time−off blower delay.

5

Most popular air handler combination.

Summary of Contents for Elite XP16024

Page 1: ...upersedes June 2007 SEER up to 17 0 2 to 5 Tons Cooling Capacity 23 200 to 58 500 Btuh Heating Capacity 21 200 to 54 000 Btuh MODEL NUMBER IDENTIFICATION P16 036 Unit Type P Heat Pump Series Nominal C...

Page 2: ...ionS SEER up to 17 0 Heating COP up to 3 82 HSPF region IV up to 8 70 2 through 5 ton Single phase power supply Sound levels as low as 74 dB Vertical air discharge allows concealment behind shrubs at...

Page 3: ...Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint Opens at 29 F and closes at 58 F Refrigerant Line Kits Refrigerant lines suction l...

Page 4: ...thout any additional controls Kit can be added in the field enabling unit to operate properly down to 30_F A Freezestat should be installed on compressors equipped with a low ambient kit A Compressor...

Page 5: ...ull load amps 1 1 1 1 1 7 1 8 Fan Motor Locked rotor amps 2 2 1 3 1 2 9 OPTIONAL ACCESSORIES must be ordered extra ComfortSenset 7000 Thermostat Y0349 S S S S Outdoor Temperature Sensor for ComfortSen...

Page 6: ...D LINE CONNECTION D G K J E F UNIT SUPPORT FEET XP16 036 TO 060 BASE SECTION H Model No A B C D E F G H J K Model No in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm XP16 024 31 787 27 686...

Page 7: ...16 024 79 0 72 0 70 0 69 5 68 5 63 5 58 0 56 5 74 XP16 036 80 5 70 5 71 5 71 0 68 5 63 5 58 5 53 5 76 XP16 048 81 0 72 5 71 5 73 0 70 5 66 0 60 5 58 5 76 XP16 060 80 5 72 5 73 5 77 5 72 5 67 0 62 5 58...

Page 8: ...F C33 24B 2 CX34 18 24C 6F C33 24C 2 CX34 19A 6F C33 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34 31A 6F C33 31A 2 CX34 31B...

Page 9: ...7 70 6 70 2010 1845 1625 3 40 2 30 CX34 25B 6F 4 G61MPV 36B 045 Factory TXV 24 000 21 600 12 900 16 00 11 70 7 70 6 70 2010 1815 1605 3 48 2 36 CX34 36B 6F 4 G61MPV 36B 045 Factory TXV 24 200 21 200...

Page 10: ...H33 36B 2F 4 G60UHV 36B 090 2 49L24 24 000 21 400 12 800 16 20 12 00 7 70 6 70 1990 1790 1580 3 50 2 38 CH33 36B 2F 4 G61MPV 36B 045 2 49L24 24 200 21 400 12 700 16 20 12 20 8 00 6 70 1955 1740 1550 3...

Page 11: ...65 2370 3 52 2 48 CR33 50 60C F 4 G61MPV 36C 090 2 49L24 36 400 33 200 20 000 16 00 12 00 8 50 7 20 3005 2765 2370 3 52 2 48 CR33 50 60C F 4 G71MPP 36C 090 2 49L24 Horizontal Indoor Coils Horizontal C...

Page 12: ...8 000 52 000 33 200 14 70 11 20 8 20 7 20 5105 4935 4350 3 08 2 24 CBX26UH 060 Up Flow Horizontal Factory TXV 56 500 52 500 33 200 15 20 11 20 8 50 7 20 4985 4710 4115 3 26 2 36 4 CBX27UH 060 Up Flow...

Page 13: ...7 20 5075 4780 4155 3 24 2 36 CR33 50 60C F 4 G71MPP 60C 110 2 91M02 55 500 53 500 34 200 14 50 10 60 8 50 7 50 5235 4855 4270 3 22 2 34 CR33 50 60C F 4 G61MPV 60C 090 2 91M02 55 500 53 500 34 200 14...

Page 14: ...SIONS Sections Description of Change ARI Ratings New rating for XP16 048 with CX34 62D coil and CX34 62D coils with furnaces ARI Ratings Removed CB30U ratings ARI Ratings Add ratings with G71MPP furna...

Page 15: ......

Page 16: ...tment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause pro...

Reviews: