XP16 − 2 to 5 Ton Heat Pump
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
XP16−024
2 TON
Air Handlers
Air Handlers
23,800 21,800 13,000 15.70 11.70 8.00 6.70 2025 1810 1600 3.52 2.38
4
CBX32MV−018/024 (Multi−Position)
Factory TXV
23,400 22,000 13,300 14.20 11.00 7.70 6.70 2110 1910 1695 3.38 2.30
3
CBX32M−018/024 (Multi−Position)
Factory TXV
24,000 22,200 13,400 15.00 11.20 7.70 6.70 2130 1885 1685 3.46 2.32 CBX26UH−018 (Up−Flow / Horizontal)
Factory TXV
24,200 21,600 12,900 16.00 12.00 8.20 7.00 1970 1725 1525 3.66 2.48
4,5
CBX32MV−024/030 (Multi−Position)
Factory TXV
24,200 21,600 12,800 16.00 12.20 8.20 7.00 1960 1715 1515 3.70 2.48
4
CBX27UH−024 (Up−Flow/Horizontal)
Factory TXV
24,200 22,000 13,300 15.00 11.50 8.00 6.70 2095 1845 1645 3.50 2.36 CBX26UH−024 (Up−Flow / Horizontal)
Factory TXV
24,400 21,600 12,800 17.00 12.50 8.50 7.20 1940 1680 1490 3.76 2.52
4
CBX27UH−030 (Up−Flow/Horizontal)
Factory TXV
24,200 22,200 13,400 15.20 11.50 8.00 7.00 2105 1820 1635 3.58 2.40
4
CBX32M−030 (Multi−Position)
Factory TXV
24,800 22,000 13,000 17.00 12.20 8.50 7.20 1995 1685 1515 3.82 2.52
4
CBX32MV−036 (Multi−Position)
Factory TXV
Up−Flow Indoor Coils
Up−Flow Coils
23,600 22,200 13,400 14.00 11.00 7.70 6.70 2145 1910 1700 3.40 2.30
3
CX34−38A/B−6F
Factory TXV
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
23,800 21,400 12,700 16.00 12.00 7.70 6.70 1975 1800 1585 3.48 2.34 CX34−36C−6F
4
G61MPV−36C−090
Factory TXV
23,800 21,400 12,700 16.00 12.00 7.70 6.70 1975 1800 1585 3.48 2.34 CX34−36C−6F
4
G71MPP−36C−090
Factory TXV
23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36A−6F
4
G60UHV−36A−070
Factory TXV
23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36B−6F
4
G61MPV−36B−070
Factory TXV
23,800 21,400 12,800 16.00 11.70 7.70 6.70 2000 1810 1600 3.46 2.34 CX34−36B−6F
4
G71MPP−36B−070
Factory TXV
24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25A−6F
4
G60UHV−36A−070
Factory TXV
24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25B−6F
4
G61MPV−36B−070
Factory TXV
24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1840 1620 3.40 2.30 CX34−25B−6F
4
G71MPP−36B−070
Factory TXV
24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CX34−36B−6F
4
G60UHV−36B−090
Factory TXV
24,000 21,400 12,800 16.00 11.70 7.70 6.70 2010 1845 1625 3.40 2.30 CX34−25B−6F
4
G61MPV−36B−045
Factory TXV
24,000 21,600 12,900 16.00 11.70 7.70 6.70 2010 1815 1605 3.48 2.36 CX34−36B−6F
4
G61MPV−36B−045
Factory TXV
24,200 21,200 12,700 16.20 12.20 7.70 6.70 1970 1815 1595 3.42 2.34 CX34−25B−6F
4
G60UHV−36B−090
Factory TXV
24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31B−6F
4
G61MPV−36B−070
Factory TXV
24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31B−6F
4
G71MPP−36B−070
Factory TXV
24,400 21,400 12,700 16.20 12.00 7.70 6.70 2005 1840 1620 3.40 2.30 CX34−31A−6F
4
G60UHV−36A−070
Factory TXV
24,400 21,400 12,800 16.20 12.00 7.70 6.70 2015 1845 1625 3.40 2.30 CX34−31B−6F
4
G61MPV−36B−045
Factory TXV
24,400 21,600 12,900 16.20 12.20 8.20 7.00 1980 1730 1525 3.66 2.48 CX34−38B−6F
4
G60UHV−36B−090
Factory TXV
24,400 21,800 13,000 16.00 12.00 8.20 7.00 2015 1765 1560 3.62 2.44 CX34−38B−6F
4
G61MPV−36B−045
Factory TXV
24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38A−6F
4
G60UHV−36A−070
Factory TXV
24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38B−6F
4
G61MPV−36B−070
Factory TXV
24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38B−6F
4
G71MPP−36B−070
Factory TXV
24,400 21,600 12,900 16.20 12.20 8.20 7.00 1980 1730 1525 3.66 2.48 CX34−38B−6F
4
G60UHV−36B−090
Factory TXV
24,400 21,800 13,000 16.20 12.00 8.20 7.00 2005 1755 1555 3.64 2.44 CX34−38A−6F
4
G60UHV−36A−070
Factory TXV
24,600 21,200 12,700 16.50 12.20 7.70 6.70 1980 1815 1590 3.42 2.34 CX34−31B−6F
4
G60UHV−36B−090
Factory TXV
Down−Flow Indoor Coils
Down−Flow Coils
23,200 22,200 13,400 14.00 10.85 7.70 6.70 2135 1925 1705 3.38 2.30
3
CR33−24A/B−F
2
49L24
23,600 22,400 13,500 14.20 11.00 7.70 6.70 2135 1885 1685 3.48 2.34
3
CR33−30/36A/B/C−F
2
49L24
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.