background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

1

VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
P/N 850,036M  REV. D  08/2007

MODELS

DIRECT VENT

ELITE

®

 SERIES

This appliance may be installed in an aftermarket perma-
nently located, manufactured  home (USA only) or mobile
home, where not prohibited by local codes. This appliance
is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow your gas suppliers
instructions.

• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.

INSTALLATION
INSTRUCTIONS

OTL Report No. 116-F-39-5

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF LIFE.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

s

l

e

d

o

M

t

l

o

v

i

l

l

i

M

s

l

e

d

o

M

c

i

n

o

r

t

c

e

l

E

M

N

5

3

-

V

D

L

E

E

N

5

3

-

V

D

L

E

M

P

5

3

-

V

D

L

E

E

N

0

4

-

V

D

L

E

M

N

0

4

-

V

D

L

E

E

N

5

4

-

V

D

L

E

M

P

0

4

-

V

D

L

E

M

N

5

4

-

V

D

L

E

M

P

5

4

-

V

D

L

E

In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or
gas fitter.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.

INSTALLER:  Leave this manual with the appliance.
CONSUMER:  Retain this manual for future reference.

A French manual is available upon request. Order Form Number
850,036CF.

Ce manuel d’installation est disponible en francais, simplement

en faire la demande. Numéro de la pièce 850,036CF.

Summary of Contents for Elite ELDV-35NE

Page 1: ...terrupteur Nepasvousservir des t l phones se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suive...

Page 2: ...l compartment cover strapped to the top of the unit GENERAL INFORMATION Note Installation and repair should be per formed by a qualified service person The appli ance should be inspected annually by a...

Page 3: ...r use with other gases unless a certified kit is used Cet appareil peut tre install dans un maison pr fabriqu e U seulement ou mobile d j install e demeure si les r glements locaux le permettent Cet a...

Page 4: ...itioning ducting Thesedirectventappliancesareuniquelysuited for installations requiring a utility shelf posi tioneddirectlyabovethefireplace Utilityshelves like these are commonly used for locating te...

Page 5: ...Vertical Wall Vent Termination Storm Collar Concentric Vent Pipe Flashing 1 inch 25 4 mm Minimum Clearance to Combustibles h c t i P f o o R H t e e f 2 1 6 o t t a l F 0 1 2 1 7 o t 2 1 6 r e v O 5...

Page 6: ...arance to combustible framing mem bers as shown in Table 2 on page 4 Iftheapplianceistobeelevatedabovefloorlevel asolidcontinuousplatformmustbeconstructed Headers may be in direct contact with the app...

Page 7: ...i l r e t n e c f o e d i s n i h c a e o t e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m e v o b a d e d n e t x e t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b...

Page 8: ...e constructed of 2x4 or larger lumber Inches mm 130 C is the required framing depth dimension when the finish material drywall thickness is 1 2 in 13mm A C l e d o M o N A B C D E 5 3 V D L E n i 6 1...

Page 9: ...N A B C D E F G H 5 3 V D L E n i 8 1 0 4 8 1 7 3 8 5 5 2 8 1 9 2 8 1 5 3 2 1 1 2 4 3 0 1 2 1 2 3 m m 1 9 0 1 3 4 9 1 5 6 0 4 7 2 9 8 6 4 5 3 7 2 5 2 8 0 4 V D L E n i 8 1 0 4 8 1 7 3 8 5 5 2 8 1 4 3...

Page 10: ...6 mm and 46 1 2 1181 mm net section lengths are available Plan the vent lengths so that a joint does not occur at the intersection of ceiling or roof joists Refer to the Vent Section Length Chart The...

Page 11: ...1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5 3 8 2 5 2...

Page 12: ...ngth may be used to secure the support straps to the vent pipe See Figure 17 Push the vent component against the collar untilitfullyengages thentwistthecomponent clockwise runningthedimplesdownandalon...

Page 13: ...is of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any o...

Page 14: ...ee el bows are used Note It is very important that the horizontal inclined run be maintained in a straight no dips and recommended to be in a slightly elevated plane in a direction away from the firep...

Page 15: ...using Secure Flex use Firestop Spacer SF4 5HF Min One Foot Vent Section Required B E L B A T V M M U M I N I H H 1 m u m i x a M t e e f m t e e f m 2 1 0 6 0 5 4 2 5 1 3 4 1 9 0 0 1 1 3 4 2 2 1 5 1 5...

Page 16: ...sections On the vertical run support the venting sys tem every 8 feet 2 4m above the fireplace vent outlet with field provided support straps Plumber s tape Attach the straps to the vent pipe and secu...

Page 17: ...ttached see Figure 28 Iftheterminusofthelastsectionisnotwithinthis distance use the telescopic vent section SV4 5LA as the last vent section For wall thick nesses greater than that shown in Figure 28...

Page 18: ...nt SF4 5HF SecureFlex firestop spacermustbeused anytime vent pipe passes through a combustible wall Note Secure Vent components rigid vent pipe and terminal are shown inthefigures SecureFlexcomponents...

Page 19: ...m u m i x a M H t e e f m t e e f m 2 1 0 6 0 4 1 3 1 9 9 0 3 4 1 9 0 5 7 6 8 2 2 4 2 2 1 4 3 0 1 6 7 2 3 5 4 2 5 1 4 1 7 6 2 4 6 9 2 7 1 4 1 7 1 8 5 2 5 7 4 3 1 2 0 2 2 6 x a M m 4 2 1 t e e f 0 4 H...

Page 20: ...nd of the adapter over the previously installed section or appli ance collar adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four inclin...

Page 21: ...s red pigtail lead and the white power supply wire to the common terminal of the outlet as shown in Figure 35 5 Connectthegroundsupplywiretothepigtail lead attached to outlet s green ground screw 6 A...

Page 22: ...cess plate opening Bring the shutoff valve on the end of the flex line over to the hard pipe and tighten with wrenches from above through the firebox opening If required access the valve by removing t...

Page 23: ...ening using the provided screws 4 as shown in Figure 37 Referto Figure41andloosenthesetscrewfor the venturi air shutter Manually actuate the air shutter through several cycles Set the air shutter to 3...

Page 24: ...s shown in the table in Figure 41 Allow the burner to operate for at least 20 minutes WARNING AIR SHUTTER ADJUST MENT SHOULD ONLY BE PER FORMED BY A QUALIFIED PROFES SIONAL SERVICE TECHNICIAN IMPORTAN...

Page 25: ...b a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room It also helps to sheetrock inside surfaces and tape for maximum air tightness and cau...

Page 26: ...e d u l c n i s t i k n o i t a n i m r e t e s e h T 9 6 9 1 H 2 T H 5 4 F S n o i t a n i m r e T e r a u q S l a t n o z i r o H x e l F t u o h t i w 7 8 L 7 7 2 1 T I K F S n i 2 1 h t i w m r e...

Page 27: ...FIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER S IN STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED HAVING JURISDICTION IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT...

Page 28: ...Turn on gas supply and test for gas leaks All Models Step 8 Refer to Figure 45 on page 27 A Remove the orifice from the manifold and replace it with the one provided in the kit See the following table...

Reviews: