Page 19
TABLE 7
Maximum Allowable Intake or Exhaust Vent Length
Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Intake and Exhaust must be same size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calculation.
Standard Termination at Elevation 0 - 4500 ft
Number
Of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
045
070
090
110
1
20
15
n/a
n/a
71
56
34
14
105
105
83
48
128
127
108
108
2
15
10
66
51
29
9
100
100
78
43
123
122
103
103
3
10
n/a
61
46
24
4
95
95
73
38
118
117
98
98
4
n/a
56
41
19
n/a
90
90
68
33
113
112
93
93
5
51
36
14
85
85
63
28
108
107
88
88
6
46
31
9
80
80
58
23
101
102
83
83
7
41
26
4
75
75
53
18
98
97
78
78
8
36
21
n/a
70
70
48
13
93
92
73
73
9
31
16
65
65
43
8
88
87
68
68
10
26
11
60
60
38
3
83
82
63
63
Standard Termination Elevation 4501 - 10,000 ft
Number
Of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
045
070
090
110
1
20
15
n/a
n/a
71
56
34
n/a
105
105
83
48
128
127
108
108
2
15
10
66
51
29
100
100
78
43
123
122
103
103
3
10
n/a
61
46
24
95
95
73
38
118
117
98
98
4
n/a
56
41
19
90
90
68
33
113
112
93
93
5
51
36
14
85
85
63
28
108
107
88
88
6
46
31
9
80
80
58
23
103
102
83
83
7
41
26
4
75
75
53
18
98
97
78
78
8
36
21
n/a
70
70
48
13
93
92
73
73
9
31
16
65
65
43
8
87
87
68
68
10
26
11
60
60
38
5
83
82
63
63