AHRI SYSTEM MATCHES - ALL REGIONS
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
EL16XC1-042-230A
TXV
40,500
15.50
13.00
CX34-44/48C
EL180UH110XE60C
8813494
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
EL195UH090XE48C
8813495
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-44/48C
EL195UH110XE60C
8813496
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
EL296UH090XE48C
8813497
EL16XC1-042-230A
TXV
40,500
15.10
12.50
CX34-44/48C
EL296UH090XV36C
8813498
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
EL296UH090XV48C
8813499
EL16XC1-042-230A
TXV
41,000
15.10
12.50
CX34-44/48C
EL296UH090XV60C
8813500
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-44/48C
EL296UH110XE60C
8813501
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
EL296UH110XV48C
8813502
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
EL296UH110XV60C
8813503
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-44/48C
SL280UH090V60C
8813504
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-44/48C
SL280UH090XV60C
8813505
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
SL280UH110V60C
8813506
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
SL280UH110XV60C
8813507
EL16XC1-042-230A
TXV
40,500
15.10
12.50
CX34-44/48C
SLP98UH090XV36C
8813508
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
SLP98UH090XV48C
8813509
EL16XC1-042-230A
TXV
41,000
15.10
12.50
CX34-44/48C
SLP98UH090XV60C
8813510
EL16XC1-042-230A
TXV
40,500
15.50
12.50
CX34-44/48C
SLP98UH110XV60C
8813511
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL180UH090E60C
8813512
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL180UH110E60C
8813513
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL180UH110XE60C
8813514
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
EL195UH090XE48C
8813515
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL195UH110XE60C
8813516
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
EL296UH090XE48C
8813517
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
EL296UH090XV36C
8813518
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
EL296UH090XV48C
8813519
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL296UH090XV60C
8813520
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL296UH110XE60C
8813521
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL296UH110XV48C
8813522
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
EL296UH110XV60C
8813523
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SL280UH090V60C
8813524
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SL280UH090XV60C
8813525
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SL280UH110V60C
8813526
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SL280UH110XV60C
8813527
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
SLP98UH090XV36C
8813528
EL16XC1-042-230A
TXV
41,500
16.00
13.00
CX34-49
SLP98UH090XV48C
8813529
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SLP98UH090XV60C
8813530
EL16XC1-042-230A
TXV
42,000
16.00
13.00
CX34-49
SLP98UH110XV60C
8813531
EL16XC1-042-230A
TXV
41,500
14.50
12.50
CX34-49
8813532
EL16XC1-042-230A
TXV
41,000
16.00
13.00
CX34-50/60C
EL180UH090E60C
8813533
EL16XC1-042-230A
TXV
41,000
16.00
13.00
CX34-50/60C
EL180UH110E60C
8813534
EL16XC1-042-230A
TXV
41,000
16.00
13.00
CX34-50/60C
EL180UH110XE60C
8813535
EL16XC1-042-230A
TXV
41,000
15.50
13.00
CX34-50/60C
EL195UH090XE48C
8813536
EL16XC1-042-230A
TXV
41,500
15.50
12.50
CX34-50/60C
EL195UH110XE60C
8813537
EL16XC1-042-230A
TXV
41,000
15.50
13.00
CX34-50/60C
EL296UH090XE48C
8813538
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-50/60C
EL296UH090XV36C
8813539
EL16XC1-042-230A
TXV
41,000
15.50
12.50
CX34-50/60C
EL296UH090XV48C
8813540
EL16XC1-042-230A
TXV
41,500
15.50
12.50
CX34-50/60C
EL296UH090XV60C
8813541
EL16XC1-042-230A
TXV
41,500
15.50
12.50
CX34-50/60C
EL296UH110XE60C
8813542
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.