Lennox EDV3530CNE-B Care And Operation Instructions Manual Download Page 2

2

Safety and  

Your Fireplace

 To prevent severe burns and injuries, install 

a screen or physical barrier to prevent direct 

contact with the glass.

To order a FREE Lennox

®

 

SAFETY GUARD 

 

for your fireplace, see details at left.

 Follow the safety instructions below 

and be sure everyone in your household 

understands this burn hazard:

The surfaces on your fireplace get  

• 

EXTREMELY HOT! 
The glass on the front 

• 

of the fireplace reaches 

EXTREMELY HIGH 

temperatures and can 

cause severe burns if touched.
Keep children away from an operating 

• 

fireplace. Closely supervise children in 

any room where a fireplace is operating 

to prevent contact with glass.
Keep clothing, furniture, 

• 

gasoline, and other 

flammable liquids away 

from the fireplace.
Even after the gas is turned off, fireplace 

• 

surfaces remain extremely hot.

 Be sure to attach the enclosed 

Safety-in-

Operation Warnings

 where you turn on your 

fireplace, to help remind everyone of the 

dangers associated with high temperatures 

(see page 5).

 Read 

Important Safety Information

 on 

page 4.

All parts of your Lennox 

Hearth Products fireplace  

get EXTREMELY HOT! 

Table of Contents

Safety and Your Fireplace

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Important Safety Information

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

4

Attaching the Safety-in-Operation Warnings

 . . . . . . . . . . . . . . . . . .  

5

General Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
Operation/Care of Your Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Gas Controls Access  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Variable Flame Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Front Glass Enclosure Panel, Removal and Installation . . . . . . . . . . . 11
Install Volcanic Stone, Embers and Logs . . . . . . . . . . . . . . . . . . . . . . 12
Burner Flame Appearance/Sooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Burner Flame Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Millivolt Appliance Checkout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Electronic Appliance Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Product Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Accessory Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Lighting Instructions – Millivolt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Lighting Instructions – Electronic  . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting Guide – Millivolt. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Troubleshooting Guide – Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Replacement Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

 

FREE

 

SAFETY

 

GUARD

 

OFFER

 

The Lennox

®

 

SAFETY GUARD

 protects against  

severe burns and injuries by preventing direct contact 

with the front glass surface of your fireplace.

To receive your FREE 

SAFETY GUARD

, call 1-800-786-7976 

or visit www.lennox.com

 

(Lennox Hearth Products / Owner Resources)

Thank you for your purchase. We appreciate your business!
Please carefully read and follow all instructions in this manual. 

Pay special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from 

your fireplace.

 

Summary of Contents for EDV3530CNE-B

Page 1: ...y damage personal injury or death vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do...

Page 2: ...mportant Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Operation Care of Your Appliance 8 Gas Controls Access 8 Variable Flame Adjustment 9 Maintenance 10 Fro...

Page 3: ...a s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las...

Page 4: ...res s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez...

Page 5: ...eelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrol...

Page 6: ...eplace any part of the control system and any gas control that has been under water WARRANTY Failure to comply with the installation and operating instructions provided will result in an improperly in...

Page 7: ...pressures that will cause damage to valve components Verify that the tanks have step down regulators to reduce the pressure to safe levels These appliances must not be connected to a chimney or flue s...

Page 8: ...es securing the door First gently depress the upper right top corner of the panel until the magnet catch pops the door free Then gently pulling the panel forward disengage the left magnet catch and al...

Page 9: ...bustible vapors H I LO W TPTH TP TH P I L O T P I L O T O N i t OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob IN OUT SIT Millivolt Gas Valve ON...

Page 10: ...ent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once if any abnormal condition is observed If the venting system is disassembled for any...

Page 11: ...t glass enclosure panel should not be re moved except to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 4 Remove the top bustle door trim and the top louve...

Page 12: ...to fitoverthegratetinesshouldbepositionedwith thesenotchesdirectlyagainstthegrate Handle logs carefully to prevent breakage Proper log placement is critical to encourage outstanding flame appearance...

Page 13: ...ating Pins Align Groove At The Bottom Of Log 1 Over The Grate And Push It Towards The Rear Align The Holes In One End Of Logs 2 3 Over The Locating Pins And Align The Grooves On The Other End Over The...

Page 14: ...Pins Align Groove At The Bottom Of Log 1 Over The Grate And Push It Towards The Rear Align The Holes In One End Of Logs 2 3 Over The Locating Pins And Align The Grooves On The Other End Over The Grate...

Page 15: ...tremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly...

Page 16: ...pearance is normal re install the lower control compartment door then proceed to finish the installation Figure 12 R E N R U B N I A M G N I T T E S G N I N E P O R E T T U H S Y R O T C A F G N I T...

Page 17: ...pplied must be replaced it must be replaced with Type AWM 105 C 18 GA wire OR OPTIONAL WALL MOUNTED ON OFF SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE CONTROL RECEIVER Factory Wired Field Wired S...

Page 18: ...d system along with an added easy to read LCD screenwhichpresentsaccesstomanyenhance ments including battery power level indicator timer mode of operation thermostatic display including room temperatu...

Page 19: ...E 8 3 L 8 8 2 C 5 4 D A R s t i K r e v u o L d e l b m e s s A o N l e d o M o N g o l a t a C o N l e d o M d e h s i l o P s s a r B d e h s u r B s s e l n i a t S 0 3 5 3 V D E 8 2 L 8 8 2 B P 5...

Page 20: ...This kit contains brass trim pieces used to finish the gaps between the wall board and the fireplace providing the appliance a brass perimeter highlight s t i K m i r T h s i n i F o N l e d o M o N...

Page 21: ...in Pewter H0941 APD45AB 45 Arch Pane Doors Antique Brass H0942 APD35EC 35 Elite Arch Pane Doors Black H0943 APD35ETI 35 Elite Arch Pane Doors Textured Iron H0944 APD35ESP 35 Elite Arch Pane Doors Sati...

Page 22: ...H3553 CLGK40C 40 Crescents Lower Grille Kit Black H3555 40 Crescents Lower Grille Kit Satin Pewter CLGK40SP H3557 CUGK45C 45 Crescents Upper Grille Kit Black EDV4540 H3559 45 Crescents Upper Grille K...

Page 23: ...s 9 EDV3530 10 EDV4035 or 11 EDV4540 on page 15 and verify the flame pattern and height displayed by the ap pliance conforms to the picture Flames must not impinge on the logs RefertoFigure13 SIT orFi...

Page 24: ...control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after th...

Page 25: ...chant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 90 secondes apr s l allumage de la veilleuse Rel...

Page 26: ...ny part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment d...

Page 27: ...Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournez la manette de r glage du gaz la position d arr t OFF 6 Attendez cin...

Page 28: ...lean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 13 on page 10 Check burner orifice for stoppage and remove Check thermopile with millivolt meter Take reading at th...

Page 29: ...ess Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert B NO Replace Ignite...

Page 30: ...3 1 55M03 1 11 Burner Assembly 55M29 1 55M30 1 55M30 1 12 Grate Assembly H4990 1 H4991 1 H4991 1 13 Venturi Air Shutter H3707 1 H3707 1 H3707 1 14 Orifice Main Burner Nat Gas 69L96 1 18L40 1 99K77 1 1...

Page 31: ...31 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts 4 8 14 7 41 40 31 30 43 33 32 34 42 36 35 16 13 2 5 6 2 3 17 18 19 11 9 1 12 21 10 15 20 EDV4035 EDV4540 EDV3530...

Page 32: ...earth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor...

Reviews: