background image

Page 4

506080-02 5/2017

Table 3. DIP Switch Function Description

Desig­
nation

Description

Off

On

Factory
Setting

1 - Cal 1

Room Temperature
Offset: 1°F

0°F

1°F

0°F

2 - Cal 2

Room Temperature
Offset: 2°F

0°F

2°F

0°F

3 - Cal +/-

Room Temperature
Offset: Sign

Posi­
tive

Neg­
ative

Positive

4 - F/C

Select Fahrenheit or
Celsius Display

F

C

F

5 - Fan
Option
(L3011C
only)

Select Heating Fan
Operation:
Electric (E) or 
Gas (G)

G

E

G

5 - Back­
up Heat
(L3021H
only)

Select Backup Heat:
Electric (Aux) or 
Gas (Dual)

Aux

Dual

Aux

Thermostat Calibration

The Cal 1, Cal 2 and Cal± DIP switches may be used to
offset or recalibrate the room temperature display. Table 4
provides DIP switch settings and corresponding tempera­
ture offset values.

L3011C Thermostats Only -

 If the fan operation DIP switch

is set on G, fan operation during the heating mode will be
controlled by the furnace, rather than by the thermostat. The
thermostat fan icon is not displayed during heating mode op­
eration, even though the fan may be energized. This setting
is used in applications which include a gas furnace. If the fan
operation DIP switch is set on E, the thermostat controls fan
operation during the heating mode. This setting is used in ap­
plications which include an electric furnace.

L3021H Thermostats Only - 

Restriction of the backup heat

functions requires the installation of the optional outdoor tem­
perature sensor (X2658). The sensor must be wired to the
subbase terminal strip T terminals. Use the backup heat DIP
switch to select either electric heat backup or gas heat back­
up.

Table 4. DIP Switch Temperature Offset

Cal 1

Cal 2

Cal +/- Temperature Offset

Off

Off

Off

+0°F (no offset)

On

Off

Off

+1°F

Off

On

Off

+2°F

On

On

Off

+3°F

Off

Off

On

-0°F (no offset)

On

Off

On

-1°F

Off

On

On

-2°F

On

On

On

-3°F

Summary of Contents for ComfortSense L3021H

Page 1: ...use have a large easy to read display and provide excellent temperature control Both thermo stat models also includes a programmable filter change re minder and a system check indicator which will notify the user of the need for equipment service Thermostat model L3011C is suitable for non heat pump single stage heat single stage cool applications that are matched with a gas or electric furnace Th...

Page 2: ...re flush with the wall 6 Align the subbase over the plastic anchors and secure it to the wall using the provided screws 7 Use a small slotted screwdriver to secure all wires to the subbase terminal block Make thermostat connec tions as follows D L3011C See table 1 and figure 1 D L3021H See table 2 and figure 2 8 Thermostat L3021H Only D For most applications E will be jumpered to W1 If separate wi...

Page 3: ...as been stored or is being used at ambient temperatures that are above 93 F The heating function will be enabled after the thermostat is exposed to ambient temperatures below 93 F for about 30 minutes DIP Switch Settings DIP Switch Settings L3011C and L3021H thermostats include five DIP switches located on the back side of the thermostat body These switches may be used to re calibrate the thermost...

Page 4: ...G fan operation during the heating mode will be controlled by the furnace rather than by the thermostat The thermostat fan icon is not displayed during heating mode op eration even though the fan may be energized This setting is used in applications which include a gas furnace If the fan operation DIP switch is set on E the thermostat controls fan operation during the heating mode This setting is ...

Page 5: ... diagrams for the thermostats are shown in figure 3 for the L3011C and figure 4 Page 6 for the L3021H COIL BLOWER WITH V DRIVE COIL BLOWER FURNACE WITH V DRIVE FURNACE L3011C L3011C L3011C L3011C Figure 3 Typical Wiring Diagrams for Condenser and L3011C Thermostat ...

Page 6: ...6080 02 5 2017 HEAT PUMP DUAL FUEL FURNACE WITH V DRIVE COIL BLOWER COIL BLOWER WITH V DRIVE FURNACE L3021H L3021H L3021H L3021H Figure 4 Typical Wiring Diagrams for Heat Pump or Dual Fuel with L3021H Thermostat ...