# 41718L098

Page 7

Figure 4

(IF USED)

(IF USED)

START

ASSIST

DEVICE

GROUND

SCREW

GROUND

SCREW

TDC

TIME DELAY

RELAY

BLUE

BLUE

TIME DELAY RELAY

(IF USED)

LOAD

C C

T'STAT

DISCHARGE THERMOSTAT

(IF USED)

DISCHARGE

THERMOSTAT

(IF USED)

1

2

5

YEL

START RELAY

(IF USED)

START CAPACITOR

(IF USED)

T2

L2

COMPRESSOR

MOTOR

FAN

MOTOR

R

S

C

CRANKCASE HEATER

(IF USED)

1

2

5

COMPRESSOR

CONTACTOR

T1

L1

T2

T1

L2

L1

L2

L1

T2

T1

SCHEMATIC OF POWER CIRCUIT

SCHEMATIC OF POWER CIRCUIT

TYPICAL

SCHEMATIC

OF CONTROL

CIRCUIT

PART NO. 38602D008

HIGH PRESSURE

SWITCH

COMPRESSOR

CONTACTOR COIL

THERMOSTAT TERMINALS

Y

OUTDOOR POWER SUPPLY

R

C

YEL

NOTE:

IF ANY OF THE ORIGINAL

WIRE IS REPLACED, THE

SAME SIZE AND TYPE WIRE
MUST BE USED.

LINE VOLTAGE - FACTORY
LINE VOLTAGE - FACTORY (IF USED)
LINE VOLTAGE - FIELD
LOW VOLTAGE - FACTORY
LOW VOLTAGE - FACTORY (IF USED)
LOW VOLTAGE - FIELD

CONNECTION

DIAGRAM

BLK

BLK

HERM

FAN

COM

START RELAY

(IF USED)

START CAP.

(IF USED)

CONNECT TO “C” AND
“Y” TERMINALS OF

INDOOR CONTROL

CIRCUIT HAVING MIN.
40 VA, 24 VOLT N.E.C.
CLASS II TRANSFORMER.

TO SINGLE PHASE

POWER SUPPLY PER
RATING PLATE WITH
MINIMUM 75°C COPPER

WIRE ONLY. CIRCUIT

PROTECTION PER
RATING PLATE.

ALT.

CONTACTOR

CRANK CASE

HEATER

(IF USED)

R

R

S

C

RED

YEL

YEL

BLK

RED

RED

RED

BLK

YEL

VIOLET

BLK

BROWN

HIGH PRESSURE

SWITCH

(IF USED)

CONTACTOR

COMP

RUN

CAP

FAN

COMP

R

COMPRESSOR

RUN

CAPACITOR

(IF USED)

LOW PRESSURE

SWITCH

(IF USED)

LOW PRESSURE

SWITCH

(IF USED)

(IF USED)

START

ASSIST

DEVICE

Summary of Contents for 41718L098

Page 1: ...re and live electrical compo nents Only trained and qualified service personnel should install or service this equip ment Installation and service performed by unqualified persons can result in proper...

Page 2: ...in any way The installation must comply with all provincial state and local codes as well as the National Electrical Code U S or Canadian Electrical Code Canada Compliance should be determined prior t...

Page 3: ...made to the system Adjustments to the system charge must also be made if an interconnecting line set other than 20 feet is installed WEATHERPROOF DISCONNECT SWITCH Minimum Clearances Figure 1 48 OVER...

Page 4: ...end of the riser must be pitched toward the compressor For long vertical risers additional traps are recommended for each additional 20 feet of pipe to insure proper oil movement A crankcase heater i...

Page 5: ...ge It should be noted that this method is not accurate at low load conditions or at outdoor ambients above 106 F 2 Using accurate gauges and temperature measuring devices determine the suction line pr...

Page 6: ...R C YEL NOTE REPLACEMENT WIRE MUST BE THE SAME GAGE AND INSULATION THICKNESS 105 APPLIANCE WIRING MATERIAL LINE VOLTAGE FACTORY LINE VOLTAGE FACTORY LINE VOLTAGE FACTORY IF USED LINE VOLTAGE FIELD LOW...

Page 7: ...OTE IF ANY OF THE ORIGINAL WIRE IS REPLACED THE SAME SIZE AND TYPE WIRE MUST BE USED LINE VOLTAGE FACTORY LINE VOLTAGE FACTORY IF USED LINE VOLTAGE FIELD LOW VOLTAGE FACTORY LOW VOLTAGE FACTORY IF USE...

Page 8: ...l maintenance items such as filters fan belts fuses or other consumable items 3 Damage caused by misuse failure to maintain properly accidents or acts of God 4 External wiring piping venting or attach...