MAINTENANCE SCHEDULE

Annually

 (before onset of burning season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspect/Clean Burner, Logs, 

and Controls

Qualified Service Technician

Inspect  valve  and  ensure  it  is  properly  operating.    Check  piping  for 

leaks.  Vacuum the control compartment, fireplace logs and burner area.

Check Flame Patterns and Flame Height Qualified Service Technician

Refer to 

Figures 20 and 21 on Page 16

 and verify the flame pattern and 

height displayed by the appliance conform to the illustration. Flames must 

not impinge on the logs.  Ensure flames are steady (not lifting or floating).

Inspect/Clean Pilot and Burner

Qualified Service Technician

Refer to 

 Figure 22 on Page 17

. Remove any surface build-up on pilot 

and burner assembly.  Wipe the pilot nozzles, igniter/flame rod and hood.  

Ensure the pilot flame engulfs the flame sensor as shown.

Check Vent System

Qualified Service Technician

Inspect the vent system at the top and at the base (within the firebox) for 

signs of blockage or obstruction.  Look for any signs of dislocation or 

deterioration of the vent components (reconnect or replace as necessary).  

Appliance Checkout

Qualified Service Technician

Perform the appropriate appliance checkout procedure detailed in this 

manual.

Replace Glowing Embers

Homeowner/Qualified Service

Technician

Remove old ember materials and vacuum the ember placement area.  

Place new embers per instructions on 

Page 13.

Periodically

 (after burning season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Clean Firebox Interior

Homeowner

Carefully remove logs, rockwool and volcanic stone.  Vacuum out interior 

of the firebox.  Clean firebox walls and log grate.  Replace logs, rockwool 

and volcanic stone as detailed in this manual.

Check Flame Patterns and Flame Height Homeowner

Refer to 

Figures 20 and 21 on Page 16

 and verify the flame pattern 

and height displayed by the appliance conforms to the picture. Flames 

must not impinge on the logs.

Clean Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this manual.   

DO NOT  TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT

.

 

WARNING: BURN HAZARD.

Turn OFF gas and electrical power to the fireplace, and 

allow it to cool before cleaning or servicing the appliance.

f i r e - p a r t s . c o m

Summary of Contents for LSM40ST-N

Page 1: ...SEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT...

Page 2: ...in Operation Warnings 5 Appliance Installation Service and Maintenance Notices 6 Appliance Operation Notices 6 Warranty Information 6 General Information 7 Inputs and Efficiencies 7 Gas Pressure Requ...

Page 3: ...5 Lisez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para...

Page 4: ...s jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la mais...

Page 5: ...nt du foyer en le faisant basculer de Marche Arr t et vice versa Nettoyez soigneusement la plaque du r cepteur mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur...

Page 6: ...and to replace any part of the control system and any gas control that has been under water Thesefireplacesaredesignedassupple mentalheaters Therefore itisadvisable to have an alternate primary heat s...

Page 7: ...lve identified IN for the inlet and OUT for the manifold side see Figure 1 on Page 8 The control valve has a 3 8 10 mm NPT thread inlet and outlet side of the valve These appliances must be isolated f...

Page 8: ...s are fitted with an ON OFF rocker switch that when toggled switches from intermittent ignition to a standing pilot see Figure 1 WARNING Young children should be carefully supervised when they are in...

Page 9: ...witch in the Remote posi tion press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen At the same time the Receiver connects to the gas valve coil and...

Page 10: ...simplybytogglingthe switchlocatedinthecontrolcompartment refer to Figure 1 on Page 5 To save energy switch to intermittent mode To have a standing pilot which will help startup in the winter by warm i...

Page 11: ...Embers Volcanic Stone and Logs Carefully follow placement instructions on Pages 13 15 All logs should fit onto cor responding pins and or log stoppers This will ensure a proper flame and safe combusti...

Page 12: ...asket surface must be clean free of irregularities and seated firmly b Position the door in front of the firebox opening with the top of the door held away from the fireplace see Figure 8 c Lower the...

Page 13: ...over the surface of the burner in the areas shown in Figures 10 and 11 Note To prevent flame impingement and soot do not use more ember material than necessary c For best glowing effect replace ember...

Page 14: ...r Log B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 5 LOG SET Item Description Item Description A Log Center D Log Top Rig...

Page 15: ...finger Rest the other end of the log on the Landing on Center Log A Figure 18 10 See Figure 18 Place hole on underside of Top Left Log E over pin on Center Log A 9 Place groove on underside of Top Rig...

Page 16: ...dy that does not soot the shutter opening must be adjusted between these two extremes Burner Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to...

Page 17: ...minimum shutter setting is designed into the venturi by four 1 16 inch tabs If the flame appears weak or sooty as described on the previous page adjust the air shutter until proper flame appear ance...

Page 18: ...8 LSM40ST P 382 lb 51 25cu ft ORDERING Replacement parts A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli a...

Page 19: ...7 AKM LSM Andirons Mission H2228 AKC LSM Andirons Classic Touch Up Paint Kit Repair of minor scratches and discoloration of the appliances black painted surfaces may be accomplished with the touch up...

Page 20: ...reate a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the front glass enclosure panel Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40 2 Dual...

Page 21: ...ervice is to be performed TO TURN OFF GAS TO APPLIANCE OPERATING INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL IN...

Page 22: ...E L APPAREIL INSTRUCTIONS DE MISE EN MARCHE AVERTISSEMENT QUICONQUE NE RESPECTE PAS LA LETTRE LES INSTRUCTIONS DANS LA PR SENTE NOTICE RISQUE DE D CLENCHER UN INCENDIE OU UNE EXPLOSION ENTRA NANT DES...

Page 23: ...firebox for signs of blockage or obstruction Look for any signs of dislocation or deteriorationoftheventcomponents reconnectorreplaceasnecessary Appliance Checkout Qualified Service Technician Perfor...

Page 24: ...cuit breakers to ensure power is on to the fireplace 2 The main burner does not light and the igniter is sparking A Gas is not reaching the fireplace Check the gas supply and gas shutoff valves B Loos...

Page 25: ...3 3 Log Set H7994 1 4 Enclosure Glass Door H2281 2 5 Spring Latch Assembly H2274 2 6 Burner Assembly H7996 1 9 Access Plate H8013 1 10 Gasket Access Plate H8012 1 11 Gas Line Tubing H8001 2 12 Connect...

Page 26: ...GH DIRECT VENT GAS FIREPLACES LSM40ST N LSM40ST P CARE AND OPERATION INSTRUCTIONS Replacement Parts ILLUSTRATION Circled numbers correspond to Replacement Parts List on previous page 1 2 4 18 25 27 3...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO SEE THROUGH DIRECT VENT GAS FIREPLACES LSM40ST N LSM40ST P CARE AND OPERATION INSTRUCTIONS Notes fire parts com...

Page 28: ...nted in U S A 2011 Lennox Hearth Products P N 506025 05 Rev C 05 2011 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Lennox Hearth Products reserves the right to make changes at any time without noti...

Reviews: