Lennox Hearth Products LMDV-33 Series Care And Operation Instructions Manual Download Page 18

18

LiGHtinG instructions – HoneYWeLL and sit MiLLiVoLt Gas VaLVe

For Your saFetY read BeFore LiGHtinG

a.

  This appliance has a pilot which must  be lighted with a piezo 

igniter. When lighting the pilot, follow these instructions 

exactly.

B.  BeFore operatinG

 smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

 

WHat to do iF You sMeLL Gas

•  extinguish any open flame.
•  open windows.
•  do not light any appliance.
•  do not touch any electrical switches.

to turn oFF Gas to appLiance

1.

  Turn remote wall switch “OFF.” The pilot will remain lit for  

normal service.

2.

  For complete shutdown, turn remote wall switch to “OFF.”

3.

  Access the lower control compartment.

4. 

Depress gas control knob slightly and turn clockwise 

                to “OFF.” Do not force.

5. 

Close lower control compartment.

LiGHtinG instructions

1.  stop! 

Read the safety information above on this Page.

2.

  Access the lower control compartment.

3.

  Turn remote wall switch to “OFF.”

4.

  Verify main line shut-off valve is open.

5.

  Push in gas control knob slightly and turn clockwise 

                

to “OFF.”

•  do not use any phone in your building.
•  immediately  call  your  gas  supplier  from  a  neighbor’s 

phone.

•  if your gas supplier cannot be reached, call the fire depart-

ment.

c.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in or turn by hand, 

do not try to repair it, call a qualified service technician. Force 

or attempted repair may result in a fire or an explosion.

d.

 Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

Note: 

Knob cannot be turned from “PILOT” to “OFF” 

  unless the knob is pushed in slightly. Do not force.

HoneYWeLL

MiLLiVoLt 

Gas VaLVe

sit 

MiLLiVoLt 

Gas VaLVe

sit 

MiLLiVoLt piLot

HoneYWeLL

MiLLiVoLt piLot

ON

OFF

PI

LO

T

L

O

HI

HI

L O W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

ti

OFF

OUT

IN

iGniter

iGniter

 

6.

  Wait five (5) minutes to clear out any gas. If you then smell gas, 

STOP! Follow “B” in the safety information above on this Page. If 

you do not smell gas, go to the next step.

 

7.

  Push in gas control knob slightly and turn counterclockwise  

                  to “PILOT.”

 

8.

  Push in control knob all the way and hold in. 

Immediately light the pilot by triggering the 

spark igniter (pushing the button) until pilot 

lights. Continue to hold the control knob in 

for about  1     minutes after the pilot is lit. 

Release knob and it will pop back up. Pilot 

should remain lit. If it goes out, repeat steps 

5 through 8.

  If knob does not pop up when released, 

stop and immediately call your service 

technician or gas supplier.

  If pilot will not stay lit after several tries, 

turn the control knob to “OFF” and  call 

your service technician or gas supplier.

 

9.

  Turn gas control knob counterclockwise                  

to “ON.”

 10.

  Close lower control compartment.

WarninG: iF You do not FoLLoW tHese instructions eXactLY, a Fire or eXpLosion 

MaY resuLt causinG propertY daMaGe, personaL inJurY or Loss oF LiFe.

Summary of Contents for LMDV-33 Series

Page 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Page 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Page 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Page 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Page 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Page 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Page 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Page 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Page 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Page 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Page 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Page 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Page 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Page 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Page 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Page 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Page 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Page 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Page 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Page 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Page 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Page 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Page 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Page 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Page 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Page 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Page 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Reviews: