background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Fan Snap Switch

Fan Speed Control

White

Ground (Green)

Black

Blower

Black (Hot)
White (Neutral)

Power Source

Blower Wiring Schematic

g

lass

 d

oor

 r

emoval

Caution:    Do  not  slam  or  strike  glass  door  or  damage 

may occur.

Do not remove the glass door while the insert is hot. To re-

move the glass door, pull forward and up on the top latches. 

Lift the glass door up and off the lower spring latch. Be 

careful not to damage or scratch the glass while handling. 

To reinstall the glass, reverse the removal steps. Do not 

operate the insert with the glass removed.

f

uel

 C

onversion

Converting your Medina™ gas insert between natural gas 

and LP can be accomplished by installing a conversion kit 

(valve regulator and burner orifice). Only a qualified service 

technician should perform the conversion.

C

onversion

  k

it

Please  see  instructions  provided  with 

conversion kit.

b

lower

 r

emoval

Unplug the power supply cord from the electrical outlet prior 

to removing the blower. The fan can be accessed through 

the back wall of the firebox. 

Caution:  Label  all  wires  prior  to  disconnection  when 

servicing controls. Wiring errors can cause improper and 

dangerous operation. Verify proper operation after servic-

ing (see the fan wiring diagram below for reference). 

Remove the insert face, glass door and log set. All of these 

items are fragile so handle them with care. Next, remove 

the nine allen head screws around the outside of the panel 

fastened to the back wall of the firebox. Rotate the top of 

this panel toward the front, remove the two wires connected 

to the fan, and then lift the panel with the fan attached out 

of the firebox. To reinstall the fan, repeat these steps in the 

reverse order.

Electrical Requirements:

This gas insert operates without an outside power source, 

however  the  blower  requires  a  120  Volt  electical  service 

outlet. Ths appliance, when installed, must be electrically 

grounded in accordance with local codes, or in the absence 

of local codes, the National Electrical Code ANSI/NFPA 70 

- latest edition. (See Operating Options for thermostat and 

ON/OFF switch information).

g

lass

 d

oor

 C

leaning

 a

nd

 r

epair

Cleaning: Do not remove or clean the glass door when hot. 

A gas door glass cleaner (available from your Lennox Hearth 

Products dealer) or windex should be used with a soft cloth 

to clean the glass. Do not use an abrasive cleaner.  

Repair: If the glass is broken in the glass door, the entire 

door (metal frame, gasket, and glass) should be replaced 

as a unit. This replacement unit is available from your Len-

nox Hearth Products dealer. Do not use substitute parts or 

materials. 

Caution: Do not operate this insert with broken glass.

Figure 0

Figure 1

(B) Door Mounting Plates

(A) Spring Handle Latches

Summary of Contents for Direct-Vent Gas

Page 1: ...lez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING If the information in this man...

Page 2: ...lation 10 Surround Panels Installation 11 Face Installation 11 Gas Line Installation 12 Gas Pressure Requirements 12 LP Natural Gas Supplies 12 Air Shutter Adjustment 12 13 Operating Instructions 13 1...

Page 3: ...bsence of local codes with the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition Your Lennox gas insert must be equipped for...

Page 4: ...ucture Combustionairisdrawnfromoutside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open WARNING THIS FIREPL...

Page 5: ...The individual manual shut off must be a T handle type valve Commonwealth Of Massachusetts Requirements Note The following requirements reference various Massachusetts and national codes not contained...

Page 6: ...ired Insert Body Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Ins...

Page 7: ...ortionofthechimneysystemshowssigns of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing th...

Page 8: ...n the screws Repeat these steps for each adjusting leg G 13 330mm 10 254mm 0 0mm H 0 0mm 2 21mm 4 102mm E H F G J C L MANTEL TRIM Mantel Trim Hearth Floor Protection E 31 1 2 800mm from Top Facing to...

Page 9: ...1installationcode Theinsertmustnotbeconnected to a chimney flue serving a separate solid fuel burning ap pliance This gas insert requires a 3 diameter listed flex liner The vent should terminate with...

Page 10: ...the flue collar is removable see Flue Collar Connection If the factory built fireplace has no gas access hole s pro vided an access hole of 1 1 2 37 5 mm or less may be drilled through the lower sides...

Page 11: ...ure loosely Face Installation The faces come with hooked brackets To install the face hang the hooked brackets on the surround brackets C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounti...

Page 12: ...lve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping...

Page 13: ...ghting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 14: ...knob slightly and turn clockwise to OFF Do not force This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air WARNIN...

Page 15: ...When the blower turns on the sound of rushing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be heard...

Page 16: ...e to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt typ...

Page 17: ...le and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for gas leaks using a gas leak test solution oCheck that the area around the...

Page 18: ...reference Remove the insert face glass door and log set All of these items are fragile so handle them with care Next remove the nine allen head screws around the outside of the panel fastened to the b...

Page 19: ...pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should...

Page 20: ...e Main Burner LP 53 H5951 Orifice High Altitude Main Burner LP 54 H5464 Conversion Kit NG to LP H5465 Conversion Kit LP to NG H6013 Blower w Mounting Bracket H5875 Blower Snap Switch H5655 Blower Spee...

Page 21: ...ase de H l appareil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FO...

Page 22: ...un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO...

Page 23: ...on about your fireplace Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 877 247 3673 Replacemen...

Page 24: ...2007 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor fo...

Reviews: