Lennox Hearth Products B-ENC0353VDE Homeowner'S Care And Operation Instructions Manual Download Page 6

6

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Periodically

 (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Front Glass Enclosure Panel

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, rockwool and decora-
tive volcanic stone and vermiculite.  Vacuum
out interior of the firebox.  Clean firebox walls
and log grate.  Replace logs, Rockwool and
volcanic stone as detailed in this manual.

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs
and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot and Burner

Checking Vent System

Appliance Checkout

Replacing Rockwool Ember Materials

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Homeowner/Qualified Services Technician

Inspect valve and ensure it is properly operat-
ing.  Check piping for leaks.  Vacuum the
control compartment, fireplace logs and burner
area.

Refer to 

Figures 6 (EDV3530), 7 (EDV4035)

or 8 (EDV4540) on page 7

 and verify the

flame pattern and height displayed by the
appliance conforms to the picture.  Flames
must not impinge on the logs.

Refer to 

Figure 9 (SIT) or Figure 10 (Honeywell)

on page 8

.  Remove any surface build-up on

pilot and burner assembly.  Wipe the pilot nozzles,
ignitor/flame rod and hood.  Ensure the pilot
flame engulfs the flame sensor as shown.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction.  Look for any signs of disloca-
tion of the vent components.

Perform the appropriate appliance checkout
procedure detailed in this manual.

Remove old ember materials and vacuum the
rockwool placement area.  Place new rockwool
as described in this document.

Maintenance Schedule

Annually

 (Before the onset of the Burning Season)

Clean as necessary following the directions
provided in this manual.  

DO NOT  TOUCH OR

ATTEMPT TO CLEAN GLASS WHILE HOT

.

Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction.  Look for any signs of
dislocation of the vent components.

Refer to Refer to 

Figures 6 (EDV3530), 7

(EDV4035) or 8 (EDV4540) on page 7

  and

verify the flame pattern and height displayed
by the appliance conforms to the picture.
Flames must not impinge on the logs.

Summary of Contents for B-ENC0353VDE

Page 1: ...ut parunqualifi installeur agencedeserviceoulefournisseurdegaz DIRECT VENT ELITE SERIES RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE OTL Report No 116 F 05 5 s l e d o M t l o v i l l i M s l e d o...

Page 2: ...these units These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 05 5 to ANSI Z21 88 2002 in Canada CSA 2 33 2002 and CAN CGA 2 1...

Page 3: ...D E 0 0 0 3 3 o N l e d o M e z i s e c i f i r O n o i t a v e l E t e e F s r e t e m t a N p o r P 0 3 5 3 V D E 0 4 3 5 0 0 5 4 0 2 7 3 1 0 5 3 0 4 V D E 6 3 2 5 0 4 5 4 V D E 3 3 1 5 WARNING FAI...

Page 4: ...tronic Appliances To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 13 and 14 of these instructions respectively Electronic appliance...

Page 5: ...NOT USE ABRASIVE CLEANERS NEVER CLEAN THE GLASS WHEN IT IS HOT Front Glass Enclosure Panel Removal and Installation These are direct vent appliances They are de signed to operate only when the front...

Page 6: ...es 6 EDV3530 7 EDV4035 or 8 EDV4540 on page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture Flames must not impinge on the logs RefertoFigure9 SIT orFigure...

Page 7: ...opening respectively Position the air shutter to the factory setting as shown in Figure 5 on page 7 Allow the burner to operate for at least 15 minutes Observe the flame continuously If it appears wea...

Page 8: ...a p o r P m m s e h c n i 0 3 5 3 V D E 8 1 2 3 8 3 5 9 5 3 0 4 V D E 5 9 8 3 0 4 5 4 V D E 5 9 8 3 Air Shutter Opening Burner Venturi Tube Air Shutter Door Orifice Increase Air Shutter Opening Decre...

Page 9: ...hardware re quired to install the unit The remote receiver can be wall or hearth mounted Deluxe Remote Control System The Model RCL T Deluxe Remote Control System has all of the features of the standa...

Page 10: ...l e n a P e c a F n a e l C o N l e d o M o N g o l a t a C o N l e d o M 0 3 5 3 V D E 6 3 L 8 8 2 C 5 3 D A R 5 3 0 4 V D E 7 3 L 8 8 2 C 0 4 D A R 0 4 5 4 V D E 8 3 L 8 8 2 C 5 4 D A R s t i K r e...

Page 11: ...between the wall board and the fireplace providing the appliance a brass perimeter highlight s t i K m i r T h s i n i F o N l e d o M o N g o l a t a C o N l e d o M d e h s i l o P s s a r B 0 3 5 3...

Page 12: ...wter H0941 APD45AB 45 Arch Pane Doors Antique Brass H0942 APD35EC 35 Elite Arch Pane Doors Charcoal H0943 APD35ETI 35 Elite Arch Pane Doors Textured Iron H0944 APD35ESP 35 Elite Arch Pane Doors Satin...

Page 13: ...CLGK40C 40 Crescents Lower Grille Kit Charcoal H3555 40 Crescents Lower Grille Kit Satin Pewter CLGK40SP H3557 CUGK45C 45 Crescents Upper Grille Kit Charcoal EDV4540 H3559 45 Crescents Upper Grille K...

Page 14: ...ION Thermopile TH TP TH TP Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105 C 18 GA wire OR OPTIONAL WALL MOUNTED ON OFF SWITCH O...

Page 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Page 16: ...ntrol knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the...

Page 17: ...clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pendant environ 90 secondes apr s l allumage de la veilleuse R...

Page 18: ...part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment doo...

Page 19: ...sition d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournezlamanetteder glagedugaz lapositiond arr t OFF 6...

Page 20: ...qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 9 on page 8 Check burner orifice for stoppage and remove Checkthermopilewithmillivol...

Page 21: ...NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert...

Page 22: ...a L 1 2 L 9 6 2 1 2 L 9 6 2 1 2 L 9 6 2 9 c i t e n g a M r o o D h c t a C 1 3 L 9 6 1 1 3 L 9 6 1 1 3 L 9 6 1 0 1 e t e l p m o C t e S g o L 2 0 M 5 5 1 3 0 M 5 5 1 3 0 M 5 5 1 1 1 y l b m e s s A...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 8 14 7 41 40 31 30 43 33 32 34 42 36 35 16 13 2 5 6 2 3 17 18 19 11 9 1 12 21 10 15 20 EDV4035 EDV4540 EDV3530...

Page 24: ...5 021M REV G 03 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Reviews: