M Series Installation Guide
revision 7 —
83
Suppression Diode Selection Notes:
-
Diode current rating:
> 1x strike current.
-
Diode break down voltage:
4x strike voltage.
-
For 12 VDC or 24 VDC strike, use diode 1N4002 (100 V/1 A) typical.
AC Door Strike Wiring
Suppression MOV Selection Notes:
-
Clamp voltage:
> 1.5x VAC RMS
-
For 24 VAC strike, Panasonic ERZ-C07DK470 typical
3
Fuse
4
TB1 on LNL-1200-16DOR
5
Suppression diode (see Suppression Diode Selection Notes below)
AC Door Strike Wiring Callouts
Callout
Description
1
AC strike
2
To AC power source
3
Fuse
4
TB1 on LNL-1200-16DOR
5
Suppression MOV (see Suppression MOV Selection Notes below)
DC Door Strike Wiring Callouts
Callout
Description
1
2
3
4
NO
NC
C
NO
NC
C
NO
NO
C
C
1
10
K4
K3
K2
K1
TB1
5
Summary of Contents for LNL-3300-M5
Page 1: ...7 3 M Series Installation Guide...
Page 4: ......
Page 9: ...HARDWARE INSTALLATION GUIDELINES...
Page 10: ......
Page 33: ...LNL 3300 M5 INTELLIGENT SYSTEM CONTROLLER...
Page 34: ......
Page 54: ...LNL 3300 M5 Intelligent System Controller 54 revision 7...
Page 55: ...LNL 1100 20DI INPUT CONTROL MODULE...
Page 56: ......
Page 65: ...LNL 1200 16DO OUTPUT CONTROL MODULE...
Page 66: ......
Page 75: ...LNL 1200 16DOR OUTPUT CONTROL MODULE...
Page 76: ......
Page 86: ...LNL 1200 16DOR Output Control Module 86 revision 7...
Page 87: ...LNL 1320 2RP DUAL DOOR CONTROL MODULE...
Page 88: ......
Page 108: ...LNL 1320 2RP Dual Door Control Module 108 revision 7...
Page 109: ...LNL 1320 S2RP DUAL DOOR CONTROL MODULE...
Page 110: ......
Page 131: ...LNL 1340 M2K FOUR READER INTERFACE MODULE...
Page 132: ......
Page 155: ...LNL 1380 8RP READER INTERFACE MODULE...
Page 156: ......
Page 170: ...LNL 1380 8RP Reader Interface Module 170 revision 7...
Page 171: ...LNL 8000 MCOM RS 485INTERFACE MODULE...
Page 172: ......
Page 178: ...LNL 8000 MCOM RS 485 Interface Module 178 revision 7...