M Series Installation Guide
revision 7 —
13
2.2
General Installation Rules
Important:
This equipment is to be installed, maintained and serviced by authorized service
persons only.
The authorized installation contractor should comply with the following rules:
•
Neatly label cables at both ends.
(For example, labels should include: controller address number/device or reader number)
•
Use individually shielded pairs of cables only. All wiring must comply with local, state, and federal
electrical codes and fire codes.
•
Obey all national, state, and local electrical and safety codes.
•
Obtain any required permits and/or inspections. Contact the local fire marshal for assistance if
necessary.
•
Safety of customer personnel is the primary consideration of the installation.
•
Neatly dress and tie or lace all wiring in a professional manner.
•
Gather together and tape all unused conductors in multiple conductor cables.
•
Shield all cabling and terminate properly.
Notes:
This is an FCC Class A product. In a domestic environment, this product may cause radio
interference in which case the user may be required to take adequate measures.
Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can
cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can
build up on the human body and then discharge when you touch a board. A discharge can be
produced when walking across a carpet and touching a board, for example. Before handling
any board, make sure you dissipate your body’s charge by touching ground. This discharges
any static electricity build-up.
2.3
Signal Transmission
•
Where practical, keep cables well separated from each other. Separate power cables from signal cables.
•
Keep the break-out at the ends of signal cables as short as possible.
•
Ground all shield drain wire(s) at the M5 controller using the grounding studs provided outside the
cabinet enclosure.
•
For communication cables between controllers, ground shield to the upstream controller only.
Note:
Do not ground both cable ends.
Summary of Contents for LNL-3300-M5
Page 1: ...7 3 M Series Installation Guide...
Page 4: ......
Page 9: ...HARDWARE INSTALLATION GUIDELINES...
Page 10: ......
Page 33: ...LNL 3300 M5 INTELLIGENT SYSTEM CONTROLLER...
Page 34: ......
Page 54: ...LNL 3300 M5 Intelligent System Controller 54 revision 7...
Page 55: ...LNL 1100 20DI INPUT CONTROL MODULE...
Page 56: ......
Page 65: ...LNL 1200 16DO OUTPUT CONTROL MODULE...
Page 66: ......
Page 75: ...LNL 1200 16DOR OUTPUT CONTROL MODULE...
Page 76: ......
Page 86: ...LNL 1200 16DOR Output Control Module 86 revision 7...
Page 87: ...LNL 1320 2RP DUAL DOOR CONTROL MODULE...
Page 88: ......
Page 108: ...LNL 1320 2RP Dual Door Control Module 108 revision 7...
Page 109: ...LNL 1320 S2RP DUAL DOOR CONTROL MODULE...
Page 110: ......
Page 131: ...LNL 1340 M2K FOUR READER INTERFACE MODULE...
Page 132: ......
Page 155: ...LNL 1380 8RP READER INTERFACE MODULE...
Page 156: ......
Page 170: ...LNL 1380 8RP Reader Interface Module 170 revision 7...
Page 171: ...LNL 8000 MCOM RS 485INTERFACE MODULE...
Page 172: ......
Page 178: ...LNL 8000 MCOM RS 485 Interface Module 178 revision 7...