The user has the ability to select which kind of events to display as well as the device 

gives the opportunity to export these logs as follow: 

 

zx w 

Excel – All the program list is exported in .xlsx format 

zx w 

CSV – All the program list is exported in .csv format 

 

 

4.2.8 - “LAN” page 

In “LAN” page (Figure No 11) the user is able to setup all the parameters of the LAN 

control of the device as follows:

System

 

 

4.2.7 - “Event log” page 

In “Event log” page (Figure No 10) the system logs all the events occurs in the device 

during its operation. These logs are divided in three different categories based on their 

priority as follow: 

 

High

           Using the red color the system logs the events which are of high priority. 

Medium

     Using the orange color the system logs the events which are of medium  

priority. 

Low

            Using the red color the system logs the events which are of low priority.

Figure No 10

Summary of Contents for Micro Line MLH-201

Page 1: ......

Page 2: ...n a properly grounded socket Insufficient grounding may cause electrocution zx w Always carefully disconnect all plugs by pulling on the plug and not on the cord Make sure the unit s power switch is turned off before removing the cord from an outlet zx w Disconnect the mains cord when the unit is not in use for long periods of time or during storms zx w Do not connect the unit to a multiple outlet...

Page 3: ...irst zx w When installing the unit make sure that an outlet is within easy reach In case of malfunction switch the unit off and unplug the power cord When the unit is not in use for a long period of time make sure that the mains cord is disconnected Connectivity zx w Before connecting the unit to other electronic devices always switch off and unplug all devices Maintenance zx w Do not spill liquid...

Page 4: ... we want to distribute HD content eg coming from STBs or blue ray to a CATV instal lation using the IPTV technology 3 2 Features zx w 4 x HD inputs zx w HDCP v1 4 support zx w Gbit IP streaming up to 64 x SPTS 4 x MPTS zx w Dual power supplies offering redundancy mode zx w Local or remote control via webserver zx w Very friendly user interface zx w Wall or rack mount options zx w SNMP v2 zx w Ultr...

Page 5: ...te can be up to 480 Mpbs 3 2 3 Dual power supplies The MLH 201 is powered from one or two external power supplies of 12VDC 2 5A In case we connect two external power supplies then they will work in redundancy mode Thus in case of failure of one of the two external power supplies the device will con tinue working without stoping 3 3 Block Diagram HD HD HD 64 SPTS 201 MLH I S 4 MPTS P HD HD ...

Page 6: ...6 3 4 Product drawing views 1 2 3 5 4 1 IPTV streaming port 2 LAN control port 3 HD inputs 4 Power supply inputs 5 Fan cooler ...

Page 7: ...lt username and password are the following Username admin Password 12345 4 2 Embedded Webserver Status 4 2 1 General page Every time that the user is connected to the device the General page Figure No 1 is loaded providing a current general status information of the device Status Inputs 1 4 In these fields the user is able to see the status of each HD input e g if the H 264 en coder is running or ...

Page 8: ... distributed via its IP outputs At the same time the device offers the whole channel list to be exported under the follow file types zx w Excel All the program list is exported in xlsx format zx w CSV All the program list is exported in csv format zx w M3U All the program list is exported in m3u 4 2 3 Block diagram page The Block diagram page Figure No 3 provides a general view of device s interna...

Page 9: ... 4 Setup 4 2 4 Input page In the Input page Figure No 4 the user is able to setup each HD input independ ently There are four tabs including all the 4 HD inputs For each tuner the user needs to pro gram the following fields ...

Page 10: ...able the HDCP function 8 LCN Set the LCN number 9 PMT PID Set the PMT PID 10 Video PID Set the Video PID 11 Audio PID Set the Audio PID Once all settings are being written the user must click the Apply button for the set tings to be saved Encoder status For each HD input the MLH 201 provides its current state e g if it is running or if it is in idle state 4 2 5 Program Selection page In the Progra...

Page 11: ...e Drop down menu from Output column Figure No 6 the user is able to as sign any program to any of the four outputs By doing the same process for each pro gram from all inputs the user is able to create the four custom multiplexes in device s output Figure No 6 Figure No 7 The status section in Figure No 7 provides a general idea to the user of the current pay load according to the selected program...

Page 12: ...ed from the device is its four outputs Peak Detection mechanism As shown in Figure No 7 there is a colored indicator of the peak detection mechanism for each output transport stream This indicates if any overflow has occurred on IP streamer s output bitrate with the following colors zx w Green No overflow occurred zx w Yellow No overflow occurred but the input bitrate is close to the output bitrat...

Page 13: ... that each program has its own IP MPTS mode Means that all the programs of the current output e g TS1 will be streamed in a single IP 2nd step For each program in SPTS mode or for the whole TS in MPTS mode the user is able to assign a multicast IP address from 224 0 0 0 to 239 255 255 255 or a unicast IP address as well as its destination port and protocol UDP or RTP By repeating the above procedu...

Page 14: ...the parameters of the LAN control of the device as follows System 4 2 7 Event log page In Event log page Figure No 10 the system logs all the events occurs in the device during its operation These logs are divided in three different categories based on their priority as follow High Using the red color the system logs the events which are of high priority Medium Using the orange color the system lo...

Page 15: ...y s IP address zx w Primary DNS Set the IP address of the primary DNS zx w Secondary DNS Set the IP address of the secondary DNS zx w Port Assign the control port zx w MAC address Depicts the MAC address of the LAN control 4 2 9 Administration page In Administration section Figure No 12 the user is able to change the default password of the webserver Figure No 11 Figure No 12 ...

Page 16: ...No 13 4 2 11 Factory default page In Factory default section Figure No 14 the user is able to apply a factory default reset either as DVB T or DVB C Figure No 14 Caution In case of factory default procedure the username and password will be reset unless we select the check box Keep username password after applying factory defaults ...

Page 17: ... to do the following 1 Export Save all the configuration is a specific file 2 Import Upload a previously save configuration file Figure No 15 4 2 13 Firmware update page In Firmware update Figure No 16 section the user is able to upload a new firmware update using the appropriate file Figure No 16 ...

Page 18: ...ect the NTP server in order for the device to receive the date and time as well as to set the timezone of his country Figure No 17 4 2 15 Info page In Info Figure No 18 section the user is able to see the serial No of the device as well as firmware and hardware versions Figure No 18 ...

Page 19: ...Service ID LCN processing Yes Output Specifications IP Streaming IP TS Out Yes Protocol UDP RTP Multicast Unicast Speed 1Gbit 480 Mbps in IP only mode IGMP support Yes v2 v3 Type MPTS up to 4 TS SPTS up to 4 HD programs Max Bitrate 480Mbps max Programming Interface Ethernet webserver Yes embedded webserver Speed 10 100 Mbps Connector RJ45 Browser compatibility Chrome Firefox Safari Opera Edge etc ...

Page 20: ...20 6 DIMENSIONS 235 00 205 00 222 00 60 00 80 00 10 50 10 00 103 23 100 50 44 00 3 00 5 00 dimensions in mm ...

Page 21: ...uipment OUT OF WARRANTY SERVICING We repair and service units of our production even once the warranty has expired if this is economically the best solution to the customer The mechanical and electronic spare parts are replaceable for a five year period after production when the circuits are assembled with discrete components When integrated circuits are used the supply of spare parts is guarantee...

Page 22: ...22 9 NOTES ...