Lemania Energy Start Booster 12/24V User Manual Download Page 9

well charged 12V battery. Depending on the size of the battery, it can take up to a few 
minutes to recharge your Booster.  
Another way to recharge a Batteryless Start Booster would be to leave it connect-
ed for 10-15 seconds 

maximum

 to the engine/alternator of the vehicle after it has 

started. The alternator will recharge it immediately. (Please make sure to remove the 
clamps after 15 seconds max.)
Make sure to only use the supplied charger. Using a non-authorized charger will void 
the warranty and can be dangerous. Batteries or Capacitors that are overcharged will 
inflate and start producing gases, which may cause an explosion or a fire. That is why 
we only recommend using the supplied charger in a well ventilated area.
 

4.  OPERATING INSTRUCTIONS

Always wear safety equipment before trying to jump start your vehicle. Make sure the 
area is well ventilated and that the terminals are clean.
Also make sure that your unit is fully charged before attempting to jump start.
If you have a 12/24V unit, make sure that the voltage selector switch is on “OFF” or 
that the red voltage connector plug is unplugged. If you have a 12V (or 24V) unit with 
ON\OFF switch, make sure it is turned OFF. Please also make sure that the cables 
are not in the path of moving parts of the vehicle’s engine.

The battery terminal not connected to the frame should be connected first. The oth-
er terminal should be connected to the frame, far from the battery and the fuel line. 
After the start, remove the frame connexion first, then the connexion from the battery 
in the same order.
Please turn OFF the air conditioning, the radio and the lights before the jump start.

A. 

BATTERY START BOOSTER

1. 

Connect the positive (red) clamp to the positive terminal.

2. 

Connect the negative (black) clamp to the frame of the vehicle (ground). 

3. 

If you have a 12/24V unit, choose the voltage with the voltage selector switch or 

 

with the voltage connector plug 12V or 24V. If you have a 12V or 24V unit with 

 

ON/OFF switch, turn it ON.  

4. 

Then start your engine and stay clear of the battery and the Start Booster 

 

while jump-starting. Make sure that it cannot fall inside the engine compartment.

5. 

Once started, first disconnect the black (negative) clamp, then place the 

 

voltage selector switch on OFF; or unplug the voltage connecter plug from the 

 

12/24V unit. 

6. 

Then disconnect the red (positive) clamp.

7. 

Store both clamps immediately in their respective placing.

8. 

Recharge the Jump Starter with the supplied automatic charger.

Important: Should the vehicle refuse to start within 10 seconds, have the Start 
Booster cool down for 3 minutes before the next attempt. If it still doesn’t start, 

09

Summary of Contents for Start Booster 12/24V

Page 1: ...START BOOSTER USER MANUAL ENGLISH 12V 24V 12 24V ENERGY LEMANIA Switzerland R...

Page 2: ...SWITCH 07 C REVERSE POLARITY ALARM 07 D 12 24V CONNECTOR SWITCH 07 E CHARGE STATUS 08 F CHARGING METHODS 08 4 OPERATING INSTRUCTIONS 09 A BATTERY START BOOSTER 09 B BATTERYLESS START BOOSTER 10 C HYB...

Page 3: ...st use It contains important safety instructions Please also make sure to recharge your Start Booster completely before every jump start attempt Make sure you only use the supplied chargers Depending...

Page 4: ...automatic or smart chargers Damaged chargers or devices must be immediately fixed or replaced Always use this device in a well ventilated area Never use in potentially explosive areas or near flammab...

Page 5: ...damaged or is leaking please have it controlled right away by an authorized agent Always attach the clamps correctly on the device after each use Batteries acid and gases can be dangerous never touch...

Page 6: ...he warranty Locations of the fuses Depending on the model of Start Booster the fuse can be located in various places On the booster itself either on the front or the back of the unit Inside the handle...

Page 7: ...ted on the Booster or on a 12 24V model To make sure it is used properly always have the booster turned OFF or disconnected before use Then connect the clamps to the vehicle s terminals or battery and...

Page 8: ...ted on the vehicle for 10 seconds maximum the voltmeter should read the voltage output of the alternator which will let you know if the alternator is working properly or not a working alternator has a...

Page 9: ...bles are not in the path of moving parts of the vehicle s engine The battery terminal not connected to the frame should be connected first The oth er terminal should be connected to the frame far from...

Page 10: ...r unplug the voltage connecter plug from the 12 24V unit 8 Then disconnect the red positive clamp and store them directly Note It is normal that your Booster will get discharged quickly It will also g...

Page 11: ...he 12 24V connector or that the Safety Fuse has not burst It could be that the connector is not connected properly Q The Booster is not taking the charge A Please check the fuse inside the charger or...

Page 12: ...12 LEMANIA ENERGY SA RUE DE BERNEX 390 1233 BERNEX GENEVA SWITZERLAND CONTACT LEMANIA ENERGY COM ENERGY LEMANIA Switzerland R CH 022018...

Reviews: