![LEM ITZ 2000-SPR FLEX ULTRASTAB Manual Download Page 12](http://html1.mh-extra.com/html/lem/itz-2000-spr-flex-ultrastab/itz-2000-spr-flex-ultrastab_manual_1874650012.webp)
Page 12/14
7November2022/Version 8
LEM reserves the right to carry out modifications on its transducers,
in order to improve them.
LEM International SA
Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
ITZ 2000-SPR FLEX ULTRASTAB
Programming example to 125 A
:
An ITZ 2000-SPR transducer head programmed to 125 A will produce 1 A when the primary current is equal to 125 A.
The current conversion ratio of the transducer is then:
Programming example to 375 A:
An ITZ 2000-SPR transducer head programmed to 375 A will produce 1 A when the primary current is equal to 375 A.
The current conversion ratio of the transducer is then:
Analog output connector
Normally the provided analog output cable should be used. It is also possible to configure your own output cable, bearing the
following description in mind.
The female 15-pin D-Sub connector Analog out connector contains the following signals:
1.
Current return
2.
Current return
3.
Current return
4.
No connection
5.
No connection
6.
Ground
7.
No connection
8.
No connection
9.
Current out
10.
Current out
11.
Current out
12.
No connection
13.
No connection
14.
No connection
15.
No connection
The pins 1 to 3 are internally shorted by rack electronics. It is the same for pins 9 to 11.
Details of further considerations relating to connect the analog output connector directly to a current measuring device can be
found in the ITZ FLEX ULTRASTAB user guide.
15
9
8
1
1
8
9
15
S
P
1 A
/
1 125
125 A
N N
=
= ⋅
S
P
1 A
/
1 375
375 A
N N
=
= ⋅