6.8.2. Metrology
Symbol
Meaning
Corresponding HTTP label and OBIS code
Data symbol: Total import energy counter
energyImportTotal - 1.0.1.8.0.255 (/livemeasure)
energyImportTotalStart (/legal) or RD[0]/RV (/ocmf)
1.0.1.8.0.1
energyImportTotalStop (/legal) or RD[2]/RV (/ocmf)
1.0.1.8.0.2
Data symbol: Total export energy counter
energyExportTotal - 1.0.2.8.0.255 (/livemeasure)
energyExportTotalStart (/legal) or RD[1]/RV (/ocmf)
1.0.2.8.0.1
energyExportTotalStop (/legal) or RD[3]/RV (/ocmf)
1.0.2.8.0.2
Data symbol: Voltage
Data is legally non-relevant
voltage (/livemeasure)
1.0.32.7.0.255
Data symbol: Current
Data is legally non-relevant
current (/livemeasure)
1.0.31.7.0.255
Data symbol: Power
Data is legally non-relevant
power (/livemeasure)
1.0.1.7.0.255
Data symbol: Temperature measured on side I1
Data is legally non-relevant
temperatureL (/livemeasure)
1.0.131.7.0.255
Data symbol: Temperature measured on side I2
Data is legally non-relevant
temperatureH (/livemeasure)
1.0.130.7.0.255
Summary of Contents for DCBM 400 Series