1) UHF inputs’ attenuator
This is manually adjustable from 0 to –20 dB.
To access the UHF attenuators’ programming menu:
-
press the “DOWN” key for 3 seconds.
-
the display will show the word
U1.00.
: this indicates that the UHF1 input attenuation level is
at zero.
-
press the “ENTER” key. The display will start blinking. This indicates the parameters’ setting mode.
-
press “UP” or “DOWN” to adjust the attenuation level from 0 to –20dB.
-
press “ENTER” again to confirm your choice. The display will return with a fixed light, this indicates
that the new setting was saved.
NOTE: the attenuation settings will be cancelled if you do not press the “ENTER” key for
confirmation at the end of the procedure.
To adjust the UHF2 and UHF3 input attenuators:
-
press “UP” or “DOWN” to choose the desired attenuator.
-
then follow the described procedure above.
To leave the remote power supply setting menu:
-
press the “UP” and “DOWN” keys simultaneously.
-
the display will return to “POWER ON” status.
2) selection of the cluster-groups’ configuration
There are 9 possible configurations:
Input UHF1 UHF2 UHF3
Cluster-groups
10 0 0
9 0 1
8 0 2
7 0 3
6 0 4
2 6 2
2 5 3
2 4 4
2 7 1
You can enter into these configurations by pressing the “ENTER” key for 3 seconds.
The display indicates the selected configuration: it views the cluster-groups corresponding to the 3
UHF inputs.
Note:
The cluster-group 2 5 3 assigns: 2 clusters to the UHF1 input, 5 clusters to the UHF2 input, 3 clusters
to the UHF3 input .
Each cluster can be programmed for a bandwidth variable from 8 to 48 Mhz. with a 8 Mhz. step, that
means from 1 to 6 UHF channels with 1 channel steps.