5.4006.8501.0
B
7-6
5.
Examine the value of the signal of the machine.
•
0 = very good
•
-20 - -25 = poor
•
< -25 = very bad
7.3.6
Test the Ultrasonic Sensor
Test
Figure 56. Test the ultrasonic sensor
1.
Manually drive the machine to a location more than 6 m (6.6 yrd) from a wall (see Manually drive the
Machine on page 5-6).
2.
Make sure no object is between the ultrasonic sensor and the wall.
3.
In the main menu of the Lely Control app, select
Test
and push
.
4.
Select
Ultrasound
and push
.
5.
If the ultrasonic sensor is on the left, push soft button
L
, else push
R
.
6.
Make sure the machine is between you and the wall.
Make sure not to interrupt the sensing beam while turning the wheel.
7.
Monitor the display of the user interface while you turn the sensing wheel.
8.
Make sure the
Pulse 1: mm
,
Pulse 2: mm
,
Pulse 3: mm
and
Filter: mm
values are 0, when the wheel is
rotating.
9.
If the values are not 0, clean the ultrasonic sensor with a tissue.
in n o vato rs in ag ric u ltu re
Summary of Contents for Lely Discovery 90 SW
Page 2: ...INTENTIONALLY BLANK 5 4006 8501 0 B innovators in agriculture ...
Page 6: ...INTENTIONALLY BLANK 5 4006 8501 0 B 6 List of Included Amendments innovators in agriculture ...
Page 16: ...INTENTIONALLY BLANK 5 4006 8501 0 B 1 2 Lely Discovery innovators in agriculture ...
Page 62: ...INTENTIONALLY BLANK 5 4006 8501 0 B 4 36 Description and Operation innovators in agriculture ...
Page 98: ...INTENTIONALLY BLANK 5 4006 8501 0 B 5 36 Operating Instructions innovators in agriculture ...
Page 124: ...INTENTIONALLY BLANK 5 4006 8501 0 B 7 8 Test and Adjustment innovators in agriculture ...
Page 146: ...INTENTIONALLY BLANK 5 4006 8501 0 B 9 2 Disposal innovators in agriculture ...
Page 149: ......