5.4008.8520.0
-
8-1
8
Test and Adjustment
8.1
Test the Ultrasonic Sensors
1.
Connect the Lely Control Plus app to the machine (see Connect the Lely Control Plus app to the
Machine on page 6-7).
2.
In the main menu of the Lely Control Plus app tap
Testing
.
3.
Tap
Ultrasound
.
•
A screen with testing results appears. The result should be
Good
or
Excellent
for both left and right
sensors.
•
If not, clean the ultrasonic sensors (see Clean the Ultrasonic Sensors on page 7-5) and do the tests
again.
•
If the test results are still not
Good
or
Excellent
, replace the ultrasonic sensor(s) .
in n o vato rs in ag ric u ltu re
Summary of Contents for 5.4008.0020.0
Page 2: ...INTENTIONALLY BLANK 5 4008 8520 0 innovators in agriculture...
Page 6: ...INTENTIONALLY BLANK 5 4008 8520 0 6 List of included Amendments innovators in agriculture...
Page 20: ...INTENTIONALLY BLANK 5 4008 8520 0 2 8 Safety innovators in agriculture...
Page 46: ...INTENTIONALLY BLANK 5 4008 8520 0 5 2 First Use innovators in agriculture...
Page 64: ...INTENTIONALLY BLANK 5 4008 8520 0 6 18 Operating Instructions innovators in agriculture...
Page 72: ...INTENTIONALLY BLANK 5 4008 8520 0 7 8 Maintenance innovators in agriculture...
Page 74: ...INTENTIONALLY BLANK 5 4008 8520 0 8 2 Test and Adjustment innovators in agriculture...
Page 80: ...INTENTIONALLY BLANK 5 4008 8520 0 9 6 Troubleshooting innovators in agriculture...
Page 82: ...INTENTIONALLY BLANK 5 4008 8520 0 10 2 Disposal innovators in agriculture...
Page 84: ...INTENTIONALLY BLANK 5 4008 8520 0 11 2 WEEE innovators in agriculture...
Page 86: ...INTENTIONALLY BLANK 5 4008 8520 0 12 2 EG Declaration of Conformity innovators in agriculture...
Page 88: ...INTENTIONALLY BLANK 5 4008 8520 0 4 Index innovators in agriculture...
Page 89: ......