7.3
Functional tests
7.3.1
Test call
We advise to start test-call to check functionality of EasyAlarm® before starting operation
7.3.2
Test alarms
Although the alarm unit with the exception of the battery is maintenance free, you should check at regular intervals all alarm
functions
8.5, in particular:
Emergency button
Door contact (misuse)
Sensor-1/3 contacts
7.3.3
Routinecall
EN81-28:2018: If no successful routine call has taken place (communication with routine call receiver, DTMF C), this is
signalled by an alternating flashing of the two EN81-70 symbols from version 8.51 on.
The routine call is performed
manually by pressing key
9
automatically when routine call is activated (announcement when switching on: Operation mode, supervision)
From version 8.51 always two hours after switching on, for older versions only after the set time span
9.4, and if the
routine call was activated with
**#1
7.4
Battery check / replacement
Change battery if you hear the following announcement after power-up: or
1. Set Function switch to OFF.
2. Disconnect EasyAlarm® from telephone network, by removing the telephone cord.
3. Open battery cover and remove battery.
4. Insert new battery and close battery compartment.
5. Reconnect EasyAlarm® to the telephone network.
Notes:
Always use fresh 9V-batteries.
Dispose the old battery properly.
Before opening battery compartment you have to disconnect the telephone-line. Otherwise you can get in contact with
telephone network voltage.
If you use backup supply voltage VIN you do not need 9V-battery. Doing so you can deactivate battery test:
*9713
27
##
*
Value
#
Value
Info
0
Battery test activated (
Factory setting
)
4
Battery test deactivated
Warning: In case of a supply power down, only calling number 1 can be dialled (emergency operation)
7.5
Maintenance
Shift function switch to OFF and remove telephone cord. Clean EasyAlarm® if necessary using a moistened cloth and dry it
afterwards.
Note:
Do not use cleaning agents or solvent.
21
Piep,piep,piep
Battery error