33
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0:off
0: Listening-in I / II / III
00: inactive
0: enabled
10: Plug&Protect (auto-detected at power-on)
input-2 is open => Normally open monitoring
input-2 is closed => Normally closed monitoring
5. Press key
.
11: Normally closed contact
The new register (bit 7 -> bit 0) will be announced
6. Slide
function switch
to OFF
10.2.3.1.2
Sensor-1 for presence verification
You can also use sensor-1 to monitor missing activity (i.e. no motion detected within a certain period) =>
Alarm message: „Emergency call due to sensor-1“. Therefore you have to activate time-out as below.
How to program presence verification time-out
Please refer to section 9.10.
10.2.3.1.3
Sensor-1 as entry-detector (Gong function)
A sensor-1 activity can also be signalled locally (Gong-function) according to the following procedure:
Example: Sensor-1 shall greet an incoming person with the pre-recorded individual message only on position I.
1. Slide
function switch
to PROG
2. Enter sequence
*
.
9
.
3
.
1
.
7
3 1
#
.
#
.
..
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
.
4. Enter sequence
0
.
0
.
0
.
0 1 1
.
1
.
0
.
.
Unused
Gong on..
Gong-type
000:
I / II / III
00: Gong
0 1
1
01: --
0: enabled
10: Individual message
1: disabled 11: Beep loud
5. Press key
#
.
.
The new register (bit 7 -> bit 0) will be announced
6. Slide
function switch
to OFF
10.2.3.2 Sensor-2 monitoring
10.2.3.2.1
Sensor-2 as alarm contact
Alarm function for sensor-2 in armed mode can be selected as following:
Example: Sensor 2 is a normally closed contact that should trigger an un-delayed silent alarm on position I/II
1. Slide
function switch
to PROG
2. Enter sequence
*
.
9
.
3
.
1
.
7
5 7
#
.
#
.
. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
.
4. Enter sequence
0
.
0
.
0
.
0 0 1
.
1
.
1
.
.
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0: off
0:off
0: Listening-in
I / II / III
00: inactive
1: on
1:on
1: Hands-free
0 0
1
01: Normally open contact
0: enabled
10: Emergency-contact according to section 10.2.3.2.2
1: disabled
11: Normally closed contact
5. Press key
#
.
.
The new register (bit 7 -> bit 0) will be announced
6. Slide
function switch
to OFF
10.2.3.2.2
Sensor-2 as emergency-sensor
If sensor-2 is enabled in section 10.2.3.2 as emergency-contact an emergency-call is triggered if the contact is
Factory default for gong-function sensor-1
000 111 00
Note:
If you do not want to
trigger an alarm on
position I you have to
disable alarm according
to section 10.2.3.1.1
Factory default for sensor-2 monitoring
00 0 000 00, => inactive
Summary of Contents for EA-8-WRL868
Page 39: ...39...