19
Notes:
After the alarm the appropriated sensor is temporarily disabled until a new status report is detected.
If a status report failure occurs quite often, please start a range check according to section 5.5.5.
All wireless sensors check their battery condition => in case of low battery the
will
announce “battery fault, zone
n
” every time the systems will be armed or disarmed!
6.5.4 ..due to tamper
If the system is armed
dials the programmed number(s) as soon the tamper of a wireless sensor
is activated and establishes a
listening-in
connection
Alarm announcement:
„Alarm due to sensor sabotage, zone n“
Important Note:
If the appropriated sensor is a key switch or remote lock (sensor function 9 and 0) the zone will
automatically deleted. Therefore you have to check, that the alarm-unit is switched off, if you want to
change the battery of the key or remote lock. Otherwise you have to re-program it.
6.5.5 ..due to missing activity (presence verification)
If there is not motion detected within a period of 24 hours EasyAlarm
®
triggers an alarm, provided
programming is set to presence verification (
section 9.10). Before starting the alarm there is a pre warning
period of ten minutes. If activation is detected (motion detected or emergency button pressed) within this
period, the alarm is cancelled; otherwise
establishes a
hands-free connection
.
Alarm announcement:
„Emergency call due to sensor “
6.6 Alarm delay / Pre warning period / Entry delay
An alarm can be delayed due to following reasons:
An alarm sensor in the area of the entrance must be delayed to have enough time to switch off the
supervision mode before
dials the first calling number.
A pre warning announcement is used to avoid false alarms (i.e. technical error like power failure, unwanted
emergency calls). During the pre warning period the alarm can be cancelled by pressing the emergency
button respectively by pressing key
0
.
.
Alarm announcement:
„Alarm acknowledged“
Notes:
The entry/exit delay 20 seconds period can be adjusted according to section 9.3
If an alarm has been triggered by pressing the emergency button, cancellation of the alarm is only possible,
if the button has been released for min. 3 seconds before pressing it again.
6.7 Phone connection
The colour of the indicator LED changes to orange during telephone connection.
6.7.1 Time-out
There is a timer running in the
phone connection
mode.
Phone connection
is kept up for two minutes. Ten
seconds before disconnection, the called person hears the announcement “abort”. He/she can restart timer using
DTMF 3 at any time.
6.7.2 Announcements
At the beginning of each
phone connection
the following information will be announced:
Individual message
followed by the cause of alarm and the instruction to acknowledge alarm by pressing DMTF 0 . In a
Listening-
in
connection you get announcement: „to speak press 1“. This announcement is repeated every 8 seconds, until
a
tone-dialling command
is entered.
Notes:
At the beginning of any
phone connection
battery state and main voltage are checked. In case a test is
negative an appropriated message will be announced.
The numbers of unacknowledged alarms is announced.