Page - 36
7. Connect any additional heat pumps as indicated, doubling up the wires as shown. See Figure 9. Confirm the same
color wires connect to the same wires on each heat pump ("Y" to "Y" and "B" to "B"). Up to 16 heat pumps can
be controlled by one heat pump.
8. Label the heat pumps appropriately as a primary unit and secondary units (Primary, Secondary 01, Secondary 02,
etc.) to simplify configuration and future operation.
9. Reattach access panels.
Multiple Heat Pump
Connection Points to "Port C"
Figure 9
10. Apply power to primary heat pump.
Confirm the mode is set to "
SYSTEM
OFF
".
11. Apply power to the next heat pump and
confirm the mode is set to "
SYSTEM
OFF
". Do this for each heat pump.
12. Program heat pumps with assigned
addresses.
Configuring Multiple Heat Pumps
Primary Heat Pump
Confirm the first connected heat pump is designated as the primary unit.
Enter "Installer Menus", then proceed
1
-
Ins
ta
lla
tion
Summary of Contents for LT1000
Page 2: ......
Page 9: ...Page 6 1 3 Dimensions Leisure Temp LT55 Leisure Temp LT400 1 Installation ...
Page 10: ...Page 7 Leisure Temp LT600 Leisure Temp LT700 LT800 1 Installation ...
Page 25: ...Page 22 Configure Call Flex Enter Installer Menus then proceed 1 Installation ...
Page 29: ...Page 26 1 Installation ...
Page 32: ...Page 29 1 Installation ...
Page 35: ...Page 32 Configure for 24 Hour Mode Enter Installer Menus then proceed 1 Installation ...
Page 36: ...Page 33 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation ...
Page 37: ...Page 34 1 Installation ...
Page 40: ...Page 37 1 Installation ...
Page 42: ...Page 39 1 Installation ...
Page 45: ...Page 42 1 Installation ...
Page 48: ...Page 45 1 Installation ...
Page 50: ...Page 47 1 Installation ...
Page 53: ...Page 50 1 Installation ...
Page 55: ...Page 52 1 Installation ...
Page 72: ......