ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN

WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone

Other Than A Certified Licensed Electrician!

All wiring MUST be in accordance with the National Electrical Code and all local codes.

W A R N I N G :   U S E   C O P P E R   C O N D U C T O R S   O N LY !

HILO AND SANTO CONTROL WIRING DIAGRAM

Conversion of the Equipment

The conversion of the equipment  package from a factory installed 120 volt system to a hardwired 240 volt system must be completed by a certified
licensed electrician.

A G.F.C.I. AND A DISCONNECT SWITCH ARE REQUIRED

The National Electrical Code requires that spas connected to 240 volts circuits be equipped with a “G.F.C.I.” and  Disconnect Switch. See National
Electric Code Articles 680-12 and 680-42.

LEISURE BAY’S SPAS ARE NOT EQUIPPED WITH A 240V G.F.C.I. OR A DISCONNECT SWITCH. A G.F.C.I. SHOULD BE
INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN

OUTDOOR LOAD CENTER

The addition of an outdoor load center such as a Siemens W0408ML 1125 or equal must be added to the circuit. This type of load center provides both
a G.F.C.I. and Disconnect Switch in a convenient configuration as required by the National Electric Code.

(

See page 9 for suggested wiring configuration)

ISOLATED, DEDICATED 240 VOLT, 30 OR 40 AMP CIRCUITS ARE REQUIRED

An isolated, dedicated 240 volt, 30 or 40 amp circuit is required to provide the power necessary to properly operate the 240V equipment package.

PERMANENTLY HARD WIRED

All 240 volt operations wiring must be permanently hard wired, installed in grounded conduit and installed in compliance with the National Electrical
Code and all local codes.

WIRE SIZING MUST MEET ELECTRICAL CODES

All installations are different. Wire sizing must meet the National Electrical Code and all local code specifications.

See pages 9 & 10 for more conversion details.

8

Summary of Contents for Celebrity Hilo

Page 1: ...SPA OWNER S MANUAL Trend Setting Innovations Since 1973 This Manual Contains IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Hilo Santo Santo S Tonga...

Page 2: ...Installed By A Certified Licensed Electrician Hard Wire Installation 11 Dip Switch Configuration 12 Control Console 14 Additional Features 15 Display Messages 16 FILTERS Skim Filter 17 WATER PURIFICA...

Page 3: ...7 Danger Risk of Injury The suction fittings in this spa are sized to match the specific water flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that t...

Page 4: ...of 98 6 F 36 6 C The symptoms of hyperthermia include 1 dizziness 2 fainting 3 drowsiness 4 lethargy and 5 increase in the internal body temperature The effects of hyperthermia include 1 unawareness...

Page 5: ...TRUCTIONS See pages 1 and 2 for other safety requirements and instructions 3 Childproof Your Spa Plan for limiting access of children Precautions such as self closing and locking gates or access doors...

Page 6: ...mpossible for the freeze protect system to fully protect your spa When severe conditions threaten we strongly recommend that you have the unit drained and winterized by a Spa Professional Properly win...

Page 7: ...connect Switch See National Electric CodeArticle 680 42 680 12 WARNING THIS G F C I PLUG PROVIDES GROUND FAULT PROTECTION FOR THE SPA AND SHOULD NEVER BE REMOVED ALTERED OR DISABLED FOR ANY REASON Thi...

Page 8: ...ss this button and power to the spa is disconnected The same action is preformed to test the G F C I circuit The second button labeled Reset also has two functions The Reset button is also the connect...

Page 9: ...bottom center screw 5 Remove side bottom screws leaving the center one for last Remove center screw while supporting panel in place 7 When Installing the panel ensure that it is completely inserted i...

Page 10: ...D WITH A 240V G F C I OR A DISCONNECT SWITCH A G F C I SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER The addition of an outdoor load center such as a Siemens W0408ML 1125...

Page 11: ...r 30 minutes In OFF position Pump turns off after 15 minutes 3 Panel Option must be OFF In ON position enables mini panel In OFF position enables current panel 4 Aux Freeze must be OFF 5 Panel Button...

Page 12: ...REQUIRED WIRING FOR 240 VOLT INSTALLATION Home Breaker Panel GFCI Load Center 10...

Page 13: ...DISCONNECT SWITCH A G F C I SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER PROVIDES BOTH The addition of an outdoor load center such as a Siemens W0408ML 1125 or equal mus...

Page 14: ...ion Pump turns off after 30 minutes In OFF position Pump turns off after 15 minutes 3 Panel Option must be OFF In ON position enables mini panel In OFF position enables current panel 4 Aux Freeze must...

Page 15: ...flashing then press the temp pad again to change The temperature will change in 1 F increments After 5 seconds the LCD automatically display the current spa temperature Jets Press the pad to turn the...

Page 16: ...change The temperature will change in 1 F increments After 5 seconds the LCD automatically display the current spa temperature Jets Press the pad to turn pump 1 and press pad to turn pump 2 Tonga Mode...

Page 17: ...s mode will maintain the thermostat setting If it does not reach the thermostat setting you may have to allow for more heating time by increasing the Heating Cycles 3 Sleep Mode SL This mode works in...

Page 18: ...of the spa will not reset automatically you may press any button to reset Check water level in spa Refill if necessary If water level is okay make sure the pumps have been primed Press any button to...

Page 19: ...loating weir and basket rotate it a 1 4 turn counter clockwise 3 Remove the floating weir and basket 4 Remove filter cartridge and wash it with a garden hose inside and out until the cartridge is clea...

Page 20: ...se Maintenance Routine No hard set rules can be established for creation of a spa maintenance program since each individual spa has its own unique location conditions and bather patterns The following...

Page 21: ...used to describe the total amount of dissolved calcium and magnesium bicarbonates as well as smaller quantities of other minerals in water Unbalanced water high in hardness can cause water to become...