14
OPERATING
Leister WELDPLAST S4 / EC4 hand extruder
Menu
Select program
Scroll
Enter
Welding parameters – Programming
The hand extruder is suitable for the following
types of thermoplastic: • PP / PE-HD / PE-LD
Programs 1 – 3
include the relevant preset values, which can be adjusted during the
course of the welding process.
The adjustments are not saved!
The free settings 1 - 4 are factory set and can be freely programmed. The para-
meters remain saved after the tool is switched off.
Setting the welding output
• Place the cursor on the «SPEED» position by pressing the
Select key (28).
• Set the welding output value (30 to 100) with the
Up (29)
or
Down keys (27).
Setting the PLAST and AIR temperature
• Place the cursor on the «PLAST» or «AIR» position by pressing the
Select key (28)
.
• Set temperature value with the
Up (29)
or
Down keys (27).
The
welding program (17)
currently set is shown in the operating display.
Welding program
Target PLAST (°C)
Target AIR [°C]
Free settings 1 – 4
230
260
Prg1 PE-LD
220
260
Prg2 PE-HD
230
260
Prg3 PP
230
260
Free
setting
1-4