background image

English - 10 -

Check the mains connection and the plug for mechanical defects!

 

Observe mains voltage:

 The mains voltage must agree with the data on the type plate of the unit. Extension cords

must have a cross section of at least 2 x 1.5 mm

2

.

Switching On:

Set the switch

 8

 to I. Set the potentiometer

 10

 as required; see reference values on the temperature scale

 5

.

The heat-up period is approx. 3 minutes.
Set the switch

 8

 to I. Set the potentiometer

 10

 as required. The set and the actual temperature are indicated

on the display

 11

. The heat-up period is approx. 2 minutes. The temperature is controlled according to

DVS Guideline 2207-3.

Switching Off:

Drehen Sie zum Abkühlen das Potentiometer

 10

 auf Position 0. Wenn das Gerät abgekühlt ist, stellen Sie

den Schalter

 8

 auf 0.

Operating Instructions

– Practical demonstrations of the applications are available free-of-charge at Leister Process Technologies as well

as through our after-sales service agents.

– Perform a test welding according to the welding instructions of the material manufacturer and the national stand-

ards or guidelines. Check the test welding. Adapt the welding temperature as required.

Temperature 
indication:

Error message:

Measures in case of error messages:

Set the potentiometer to the 0 position or disconnect the unit from mains for approx. 5 seconds (automatic reset).

Allow the unit to cool down. Check air flow/air filter and the mains voltage. Set the potentiometer to the required

value and connect the unit to mains again.
When an error message is indicated afterwards again, contact an after-sales service agent and report the error

code.

– Check mains connection and plug for interruption and mechanical damage.
– Before any work on the unit: Pull the mains plug.

– For secure and proper operation, keep the unit and the ventilation slots clean at all times.
– Use only original Leister accessories.
– When contaminated, clean the air filter

 9

 of the switched off unit using a brush. Replace a damaged or heavily

contaminated air filter.

– The motor of the fan automatically switches off when the carbon brushes reach the minimum length. The operat-

ing lifetime of the carbon brushes is approx. 1600 hours. Have carbon brushes replaced through an authorized

Leister after-sales service.

If the unit should fail despite the care taken in manufacturing and testing procedures, repair should be carried out

by an authorized Leister after-sales service agent.

For this tool, we generally provide a warranty of one (1) year from the date of purchase (verified by invoice or deliv-

ery document). Damage that has occurred will be corrected by replacement or repair. Heating elements are

excluded from this warranty.
Additional claims shall be excluded, subject to statutory regulations.
Damage caused by normal wear, overloading or improper handling is excluded from the guarantee.
Guarantee claims will be rejected for tools that have been altered or changed by the purchaser.

Putting into Operation

 

Digital Indications/Error Messages

A

B

A

B

B

Actual value
Set value

Resolution 5 °C or 10 °F 

Error message
Error code

Maintenance, Service and Repairs

Warranty

Subject to change without notice

Summary of Contents for Triac PID

Page 1: ...TRIAC PID 2 3 4 Titelseite qxd 15 6 2005 14 30 Uhr Seite 1 Leister Technologies AG Galileo Strasse 10 CH 6056 Kaegiswil Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leist...

Page 2: ...Deutsch Bedienungsanleitung 4 English Operating Instructions 7...

Page 3: ...A B 1 2 3 4 6 8 9 10 5 Triac S Triac PID 7 1 2 3 4 6 8 9 10 5 7 11 3 1 3 1 1 1 1 1...

Page 4: ...erreichen und entz nden die sich nicht sichtbar hinter Verschalungen in Decken B den oder Hohlr umen verbergen ber pr fen Sie vor Arbeitsbeginn den Arbeitsbereich und verzichten Sie bei unklarer Situa...

Page 5: ...D se Die D se 1 1 auf das Heizelementrohr 3 1 aufschrauben und mit Gabelschl ssel SW 17 festziehen D sen nicht im Lieferumfang enthalten Technische Daten TRIAC S TRIAC PID Spannung V 42 100 120 200 2...

Page 6: ...d anschlie end erneut eine Fehlermeldung angezeigt Service Stelle kontaktieren und den Fehlercode angeben Netzanschlussleitung und Stecker auf Unterbrechung und mechanische Besch digung pr fen Vor all...

Page 7: ...s in ceilings floors or cavities and ignite them Inspect the work area before starting to work and in case of doubt abstain from using the hot air tool Do not point the unit at the same spot for exten...

Page 8: ...shirts overalls and hats 4 Work in one room at a time Furnishings should be removed or placed in the center of the room and covered Work areas should be sealed off from the rest of the dwelling by se...

Page 9: ...nozzle 1 1 onto the heating element tube 3 1 and tighten using an open end spanner size 17 mm Nozzles not included in the delivery scope Technical Data TRIAC S TRIAC PID Voltage V 42 100 120 200 230...

Page 10: ...ct the unit to mains again When an error message is indicated afterwards again contact an after sales service agent and report the error code Check mains connection and plug for interruption and mecha...

Page 11: ......

Page 12: ...0 Leister Technologies AG Galileo Strasse 10 CH 6056 Kaegiswil Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com Leister Technologies Deutschland GmbH Rohrstr 16 D...

Reviews: