2
Danger!
When opening up the tool, live components
and connections are exposed. Therefore, before open-
ing it, unplug the tool to ensure disconnection from
the mains.
The tool must be grounded with the protective con-
ductor.
The
voltage rating
stated on the tool should corre-
spond to the mains voltage.
Protect tool from
damp and wet.
Use thermal overload protection switch.
Pay attention to the direction of rotation.
230
400
Design
Voltage for three-phase supply
V~
Voltage for single phase supply
V~
Condensor for single phase
mF
Capacity
W
Frequency
Hz
Air flow
l/min.
Static pressure
Pa
Noise level
dB (A)
Environmental protection
DIN 40050
Diameter of air intake (external Ø) mm
Diameter of air outlet (external Ø) mm
Ambient temperature
°C
Weight
kg
Size (L x B x H)
mm
radial blower
3 x 230 – 254
3 x 380 – 440
1 x 230 – 254
12
250
50 / 60
4700 / 6000
1000 / 1400
61
IP 54
80
60
<60
9,0
280,5 x 289 x 280
WARNING
CAUTION
TECHNICAL DATA
100 Pa = 1 mbar