13
Technical data
Technical data and specifications are subject to change without prior notice
Type
LE 5000 DF
HT
Voltage V~
3
×
230
3
×
400
3
×
200
3
×
400
Frequency Hz
50 / 60
Power consumption
kW
8
4.5 6.5 7.5 8
7
7.5
11
Max. air outlet temperature
°C
700
900
Max. air inlet temperature
°C
150
150
Min. air volume (20°C)
l/min.
560
320 460 530 560
380
400
580
Max. static pressure.
bar
1
Emission level
LpA (dB)
< 70
Weight kg
1.9
3.1
3.1
Size mm
page 3
Mark of conformity
Approval mark
Protection class I
Type
LE 10 000 DF
HT
Voltage V~
3
×
400
3
×
480
3
×
400
3
×
480
Frequency Hz
50 / 60
50 / 60
Power consumption
kW
5.5
11
17
8
16
15
Max. air outlet temperature
°C
650
900
Max. air inlet temperature
°C
150
150
Min. air volume (20°C)
l/min.
420 840 1300 610 1220
800
Max. static pressure.
bar
1
Emission level
LpA (dB)
< 70
Weight kg
3.4
4.0
Size mm
page 4
Mark of conformity
Approval mark
Protection class I
Type
LE 10 000 DF HT 3 × 400V/22kW
Voltage V~
3
×
400
Frequency Hz
50 / 60
Power consumption
kW
22
Max. air outlet temperature
°C
900
Max. air inlet temperature
°C
100
Min. air volume (20°C)
l/min.
1200
Max. static pressure.
bar
1
Emission level
LpA (dB)
< 70
Weight kg
6.1
Size mm
page 5
Mark of conformity
Approval mark
Protection class I