Danger! 

Unplug the tool before opening it, as live compo-

nents and connections are exposed.

The equipment must be operated 

with supervision.

For personal protection, we strongly recommend the
tool to be connected to an 

RCCB 

(

R

esidual 

C

urrent

C

ircuit 

B

reaker) / 

GFCI 

(

G

round 

F

ault 

C

ircuit 

I

nterrupter)

before using it on building sites.

The voltage rating 

stated on the tool must correspond to

the line/mains voltage.

Risk of injury 

from touching the cutting blade.

Protect the tool from 

damp and wet.

Use earmuff!

FI

120

230

2

WARNING

CAUTION

Risk of injury 

by ejected particles. Ejector pipe and

dustbag must be fitted.

Electrical safety    

4

double insulated

APPROVAL MARKS

TECHNICAL DATA

This tool is 

CCA

certified   (

C

ENELEC 

C

ertification 

A

greement).

Voltage

V~

120, 230

Frequency

Hz

50 / 60

Power consumption

W

350,                 700

Cutting speed 

rpm

Pos 1: 14 500,  Pos 2: 18 000

Noise emission level

L

pA

(dB)

84

Sound pressure level

L

WA

(dB)

100

Vibration acceleration

a

hw

(m/s

2

)

1.6

Groove depth adjustment mm

0 – 4, infinitely

inch

0 – 3/16

Weight

kg

6,7 

}

with 3 m (10 feet.) cord and

lbs

14,7   ejector pipe

Size

mm

240

×

205

×

255 

inch

9,4

×

8

×

10

3

Summary of Contents for GROOVER

Page 1: ...and keep for future reference Cutting welding grooves into floor coverings of tiles rolls nap tiles and rolls GB OPERATING INSTRUCTIONS APPLICATION LEISTER Process Technologies Riedstrasse CH 6060 Sar...

Page 2: ...g blade Protect the tool from damp and wet Use earmuff FI 120 230 2 WARNING CAUTION Risk of injury by ejected particles Ejector pipe and dustbag must be fitted Electrical safety 4 double insulated APP...

Page 3: ...f your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use to cord...

Page 4: ...before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the r...

Page 5: ...switch 4 Cutting speed switch 5 Handle 6 Hand rest 7 Scale for depth adjustment 8 Control knob for depth adjustment 9 Adjustable guide roller 10 Rear roller 11 Tracking wheel 12 Spacers 13 Roller axl...

Page 6: ...rows on the tool red with the grooving line The adjustable guide roller 9 should run inside the grooving line and the rear roller 10 in the groove Activate the locking button 3 Switch on the operating...

Page 7: ...llustration number not to scale Tungsten carbide tipped blade 110 3 5 mm trapezium profile Tungsten carbide tipped blade 110 4 mm round profile Tungsten carbide tipped blade 110 2 5 mm round profile T...

Page 8: ...urs using original LEISTER spare parts Guarantee and liability are in accordance with the currently valid general business and sales conditions LEISTER Process Technologies rejects any guarantee claim...

Reviews: