Leica T-Scan5 Quick Start Manual Download Page 6

397

CHAPTER 14 

 MEASURING WITH LASER TRACKERS

Figure 14-86. 

 c

Fi

Fi

Fi

Fi

gure 14-86. 

 c

5. 

You can tell you have a successful connection to both the T-
Scan  Controller  and  the Tracker  once  you  see  the  Status  in-
dicator  in  the  bottom  right  of  the TwinCAT  software  report 
a green connected status. At that point you can close out of 
TwinCAT. 

Running the T-Scan Interface in SA:

1. 

Add the Instrument (Instrument>Add…) and choose the ap-
propriate Leica Tracker (AT901 or AT960)

2. 

Start the Interface through the menu Instrument>Run Inter-
face Module and choose Leica TScan. (Do not connect using 
the Laser Tracker Interface) (see 

Figure 14-87

):

Summary of Contents for T-Scan5

Page 1: ...CA 47 cable between the T Scan and Tracker controller s signal port the trigger port is not used The AT901 uses the MCA 36 cable which has a dual end for the tracker sig nal line and trigger connectio...

Page 2: ...ration 1 Open the Emscon TransferTool enter the tracker IP and press Test 2 In the Transfer to emScon section press Parameter File and browse to the emsys file for the t scan provided on the USB disk...

Page 3: ...ile Network Configuration 1 Configure your local area network connection as follows 2 Go to Control Panel Network and Internet Network and Sharing Center 3 Open the Local Area Network Connection prope...

Page 4: ...ll the TwinCAT Engineering Software which will man age the dual network communication between the tracker and the T SCAN system This software should be available on your USB drive and will be called T...

Page 5: ...UAL Figure 14 85 c Figure 14 85 c 4 Perform a Broadcast Search and look for the AMS NetID of the controller which should show up on the network list When it does select it and set it to use IP Address...

Page 6: ...or in the bottom right of the TwinCAT software report a green connected status At that point you can close out of TwinCAT Running the T Scan Interface in SA 1 Add the Instrument Instrument Add and cho...

Page 7: ...4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87...

Page 8: ...tart Instrument Interface Argument 3 controls the allow able interface types Include 0 laser tracker 1 Leica Automa tion Interface Control interface or 2 Leica T Scan Instrument Operational Check Sele...

Page 9: ...urement Mode Causes the T Scan to Stop Scan ning Leica Automation Interface Hardware Setup Before starting the AIC driver it s necessary to ensure that all hard ware connections are complete The AT 90...

Reviews: