MENU Setting
*) Applicable to SPRINTER 100M/200M only
740359-1.
1
.0en • Leica Geosystems AG • CH-9435 Heerbrugg (Switzerland) • Phone +41 71 727 31 31 • Fax +41 71 727 46 73 • www.leica-geosystems.com
No. Sub Menus
Selections
Descriptions
1. Input PtID *
To input user point ID
2. Input Reduced
Level (RL)
Input for Benchmark value / Reference Reduced Level
3. Data
Manager *
View, Delete, Down-
load
Viewing of individual recorded data and deleting of specific measuring data,
Deleting of all data, Transferring of data via PC software.
4. Recording *
Memory, External,
OFF
Data can be recorded in the internal memory of the instrument or externally to
the external device such as data collectors. If the recording is set OFF, then the
captured data will not be stored.
5. Adjustment
None
Adjustment program
6. Inverse Staff
ON=Inverted mode
OFF=Upright mode
Setting of measurement to Inverted Staff. By default or on power on, the mode
is always set to OFF.
7. Contrast
10 levels of select.
Optimum contrast setting for LCD display. Contrast is set to 50% ex factory.
8. Unit
M, INT ft, US ft, Ft in
1/8in
Display Unit setting in meters, international feet, US feet, and ft in 1/8in
9. AutoOFF
ON 15 min / OFF
Power saving function. If set to ON 15 min, the instrument will switch off about
15 minutes after the last key press. In the case of OFF, the instrument will be
permanently switched on
10. Rounding
Standard/Precise
Standard = 0.001m / 0.01ft for height and 0.01m / 0.1ft for distance.
Precise = 0.0001m / 0.001 ft for height and 0.001m / 0.01 ft for distance.
In Ft in 1/8 inch; Precise/standard = ft-inch-1/8 inch for height & distance.
11. Beep
ON/OFF
Acoustic signal trigger key ON or OFF
12. RS232 *
Baudrate
Parity
Stop Bit
Data Bit
1200, 2400, 4800, 9600, 19200, 38400
None, Odd, Even
1, 2
7, 8