SMART TARGETING - PAIRING : SHORT PRESS 
 
If I press the Smart Targeting key short, the device starts to rotate 

– what does this mean? 

 
 

  

 
 
Pressing the Smart targeting function shortly means that the device goes back to the 0° (default 
position in the middle). This is the position, where you have on both sides a +4° and -4° searching 
range for the Smart Targeting. At a distance of 20m, this means a transverse distance of +/- 1.4 m 
up from the 0° position (=total: 2.8m). You can check the laser position with the 3 lines, which are 
stamped below the handle. The 0° position is achieved, if the line from the metallic base plate is in 
the middle of the 3 lines from the plastic housing ( Make sure, that the feet are folded in). 
 
 

SMART TARGETING OVER DISTANCE  
 
The Smart Targeting function does not work on longer distances? 

The Smart Targeting function (automatic alignment) works only until 50m. The distance range is 
dependent on the surrounding conditions (obstacles, other radio controlled devices,...). If it is used 
above 50m, the Smart Targeting could be slower or it could occur, that it even does not catch the 
laser beam properly. The distance range for the standard line location of the XCR catch receiver is  
longer, it works up to 100m.  
 
 

 
If the sensitivity is enlarged to 5mm, this supports the targeting.  

We recommend to use Smart Targeting function at a minimum distance of 5m. 

 
 
 
 

SMART TARGETING 

– LASER BEAM ALREADY ON WINDOW 

 
The Smart Targeting function cannot be started if the laser beam is visible on the receiver 
window? 

If the laser beam is visible on the window, it was already targeted by the XCR catch receiver. In 
this position the Smart Targeting function will not start if you press the function key long. If you face 
this circumstances, remove the XCR Catch receiver completely outside the laser beam, press 
again the Smart Targeting key long until the 2 LEDs blink. The Smart Targeting function starts now 
and the XCR Catch can be moved back to the original position. Another option to solve this issue, 
is to use the continuous targeting mode. Press Sensi Smart targeting key simultaneously 
and the laser beam follows the XCR catch receiver continuously until it is stopped by pressing the 
Smart targeting key again. 