7
Technical Data
7.1
Angle Measurement
Available angular
accuracies
Standard deviation
Hz, V, ISO17123-3
Display resolution
["]
[mgon]
["]
[°]
[mgon] [mil]
1
0.3
0.1
0.0001 0.1
0.01
2
0.6
0.1
0.0001 0.1
0.01
3
1.0
0.1
0.0001 0.1
0.01
5
1.5
0.1
0.0001 0.1
0.01
Absolute, continuous, diametric. Updates each 0.1 to 0.3 s.
7.2
Distance Measurement with Reflectors
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Standard prism
(GPR1)
1800
6000
3000
10000
3500
12000
3 prisms
(GPR1)
2300
7500
4500
14700
5400
17700
360° prism
(GRZ4, GPZ122)
800
2600
1500
5000
2000
7000
Reflector tape
60 mm x 60 mm
Prism mode
150
500
250
800
250
800
Non-prism mode,
R500
300
1000
500
1600
>500
>1600
Non-prism mode,
R1000
600
1950
1000
3300
>1000
>3300
Mini prism
(GMP101)
800
2600
1200
4000
2000
7000
360° Mini prism
(GRZ101)
450
1500
800
2600
1000
3300
Shortest measuring distance:
1.5m
Range
Description
A
Strong haze, visibility 5km; or strong sunlight, severe
heat shimmer
B
Light haze, visibility about 20km; or moderate sun-
light, slight heat shimmer
C
Overcast, no haze, visibility about 40km; no heat
shimmer
Accuracy refers to measurements to standard prisms.
Accuracy
Characteristics
Range
Atmospheric condi-
tions
Accuracy
48
Technical Data
Summary of Contents for FlexLine TS10
Page 1: ...Leica TS10 User Manual Version 1 0 English...