background image

8

Functions

Leica DISTO™ DXT 776113

GB

D

N

S

FIN

DK

SLO

TR

GR

ROK

RUS

SK

CZ

H

PL

EST

LT

LV

BG

RO

Adding and subtracting areas

Calling up the area function and measuring areas.

Press  

or  

.

1x briefly: takes first distance measurement 
(e.g. length)

1x briefly: takes second distance measurement 
(e.g. width)

The result of the second area measurement, "+" flashes. 

1x briefly: confirms the addition; the added area 
results are displayed in the summary row.

Volume function

2x briefly: the 

 symbol is displayed.

1x briefly: takes first distance measurement 
(e.g. length) 

1x briefly: takes second distance measurement 
(e.g. width) 

The result of the area measurement from the values 
already measured is displayed in the summary row.

1x briefly: takes the third distance measure-
ment (e.g. height). The value is displayed in 
intermediate line 1.

The calculated volume appears in the summary line, 
the last three measured values appear in interme-
diate lines 1, 2, 3.
Press the 

 button 

for longer

 to display additional 

room information such as circumference 

ceiling/floor area 

, surface area of the walls 

.

Indirect Measurement

The instrument can measure distances with the 
Pythagoras method. This procedure facilitates in 
measuring distances that are difficult to access.

)

Adhere to the prescribed sequence of meas-

urements:

All target points must be vertical or horizontal on 
the surface of the wall.

The best results are achieved when the intrument 
is rotated around a fixed point (e.g. the stop 
bracket is fully extended and the instrument is 
placed against a wall).

To take the measurement, the minimum/
maximum function can be called up. The minimum 
value is used for measurements that must be at 
right-angles to the target; the maximum distance 
is used for all other measurements.

)

Make sure that the first measurement and the 

distance to be measured are at right angles. Use the 
minimum/maximum function.

Summary of Contents for DISTODXT

Page 1: ...Leica DISTO DXT The original laser distance meter...

Page 2: ...al and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted uses Me...

Page 3: ...es The manufacturers of non Leica accessories for the Leica DISTO are responsible for developing imple menting and communicating safety concepts for their products They are also responsible for the ef...

Page 4: ...E key 7 HISTORICAL MEMORY UNITS key 8 CLEAR OFF key Display 1 Laser ON 2 Reference front rear end piece tripod 3 min max display 4 Battery status 5 Area volume 6 Info symbol 7 Pythagoras 8 Historical...

Page 5: ...ttery compart ment seals Operation Measuring Conditions Range Range is limited to 70 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a targe...

Page 6: ...uch a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switching...

Page 7: ...naps in push the stop bracket with a little force to the right side the stop bracket can now be completely unfolded The device automatically recognises the measurement position and adjusts the followi...

Page 8: ...mum value Switching on continuous measurement see above The corresponding maximum and minimum values are displayed Functions Addition Subtraction Distance Measurement 1x briefly the next measurement i...

Page 9: ...e appears in the summary line the last three measured values appear in interme diate lines 1 2 3 Press the button for longer to display additional room information such as circumference ceiling floor...

Page 10: ...s pressed for along time while measuring a distance maximum or minimum contin uous measuring is activated Indirect measurement determining a distance using 3 auxilliary measurements 2x briefly the sym...

Page 11: ...either displayed with or Error The following errors can be corrected Cause Correction 204 Calculation error Repeat procedure 252 Temperature too high Let device cool down 253 Temperature too low Warm...

Page 12: ...lectromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment WARNING The Leica DISTO conforms to the most strin gent requiremen...

Page 13: ...telescopes can be hazardous Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not stare into beam Do not...

Page 14: ...nty applies Disposal CAUTION Flat batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local r...

Page 15: ...14 Appendix Leica DISTO DXT 776113 GB D N S FIN DK SLO TR GR ROK RUS SK CZ H PL EST LT LV BG RO...

Page 16: ...Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent f...