Type
Value
Typical search time in field of view
1.5 s
Field of view
1°25’/1.55 gon
Definable search windows
Yes
Type
Description
Principle
Digital image processing
Type
Infrared laser
7.5
AutoSearch
Reflector
Range
[m]
[ft]
Standard prism
(GPR1)
80
260
360° prism
(GRZ4, GRZ122)
80
260
360° mini prism
(GRZ101)
Not recommended
Mini prism
(GMP101)
80
260
Measurements at the vertical limits of the fan or under unfavourable atmo-
spheric conditions may reduce the maximum range. (*optimally aligned to the
instrument)
Shortest measuring distance:
1.5 m
Type
Value
Typical search time
20 s
Default search area
Hz: 400 gon, V: 40 gon
Definable search
windows
Yes
Type
Description
Principle
Digital signal processing
Type
Infrared laser
7.6
LOC8 Theft Deterrence and Location Device (optional)
Battery
Voltage
Capacity
Li-Ion
800 mAh
Recharged by the total sta-
tion battery when instrument
is switched on
Up to 3 days
Depending on mode of oper-
ation and cellular network
conditions
Searching
Characteristics
Range
Searching
Characteristics
Internal battery
Technical Data