DELTA
Installation Manual
Edition July 2013
DELT
∆
∆
∆
∆
platform lift
page 10 of 24
Installing of the charging station/limit assembly
The position of the charging stations/limit assembly has to be adjusted so the
limit
switches
on the lower carriages are pressed by the
mechanical stop
at the correct spot.
Connect the stations according to the electric
diagram. The
positive connection
goes to the
charging ramps (copper material). The
negative
connection
goes to the rail. Make sure there
cannot be a short circuit between the copper and
the rail. This could destroy the charger! Connect the
upper and the lower copper charging ramp with a
single phase cable. This cable can run behind the
steel profile under the lower rail.
Fix the charging station with the limit assembly onto the steel profile in the upper and lower
landing. Fine adjust limit switches S27 and S28 if necessary with the slot hole under the
carriage covers.
The
plastic buffers on the lower end of the backside
of the carriage should touch down slightly on the
bottom in the
lower stop position
. The lower
limit assembly should be placed accordingly!
In the
upper stop position
the platform should
be in one line with the landing height, so the
wheelchair driver can leave the platform
horizontally, without any ramp inclination!
Install the
battery charger
at any convenient
place close to the upper or lower charging
stations. Make sure there is no collision between the battery charger and the moving
platform in case of wall fixing of the rail.
Plastic buffers should just
touch down on the bottom!
Fine adjustment of the stop
can be made by moving the
limit switch fixing
Fit the limit assemblies on the upper
and lower landing to the steep plate.
Loosen screws and
move plate up or
down
Positive
Negative