Fault detection and trouble shooting
The lift is equipped with a number of electrical and mechanical safety features. If the lift is
not working check the following points:
Next to the main power switch are 3 LEDs. The left and the right LED indicate the
directional obstruction sensors on the drive unit and trolleys. The middle LED indicates the
safety circuit. If all 3 Leds are turned off the safety circuit is open.
The safey circuit consists of the following switches:
Overspeed governor switch S10
Seat rotation switch SR2
Ultimate limit switch S22
Handwheel switch SA5
The directional obstructions sensoers consist of the following switches (left/right):
Upper trolley S13/S12
Lower trolley S27/S28
Lateral drive unit SK-1/SK-2
Footrest (directional) EK-R/EK-L