Stairlift ALPHA Installation Manual
Edition March 2014
ALPHA
stairlift
page 13 of 14
Troubleshooting
The
seat does not react at all from the call station or the armrest control
Check if LED 24 is on. If not the safety circuit is broken (swivel seat switch,
overspeed switch and ultimate stop switch)
Check if the overspeed governor is not engaged. If engaged LED 16-23 is off.
Check if the ultimate stop switch is pressed. If pressed LED 17-23 is off.
Check if the seat is in the correct position and not rotated. The seat swivel switch
must not be pressed! If it is pressed LED 18-23 is off.
The
seat does only react from the remote call stations but not from the armrest
control joystick
Check if the armrest is folded down correctly and if the key switch in the armrest is
turned on.
The
seat does only react from the armrest control and not from the control stations
Check if the LED on the external control shows a blinking green light. If the lift is
blinking orange then the receiver does not receive the signal. If it is blinking green it
is receiving correctly.
If you press the drive up or down button the LED 8 or 9 should come on. If not the
board does not receive the drive command from the receiver.
The
seat drives only in 1 direction
Check the LED 25 and 26. If one of the 2 LEDs is off then the contact pads on the
drive unit or the trolley are blocked in the driving direction that is not working.
The
lift makes a beeping sound (out of charging sound) although it is located in the
charging station and LED 6 is OFF
Check that the charging pin in correctly in contact with the copper charging plate on
the charging station.
Measure if the board receives the ground from the rail (it is transmitted through the
drive pinion in the chassis) through the fixing screws of the board to the chassis.
The
lift makes a being sound (every 2,5 second – low battery voltage)
is located in or
outside the charging station
Check if LED 1 is on. If not this indicates weak battery voltage.
Summary of Contents for ALPHA