LEGRAND Wattstopper EQ41-LCAP Installation Instructions Manual Download Page 5

5

No: IS-00711 – Rev. A

DEVICE SETTINGS OVERVIEW 

(continued)

3. Access and Permissions

 - Edit all 

user accounts and passwords within 

this screen.

By pressing

 Administrator

, access 

user role edit screen to set user name, 

access level, password, manage 

view order, default view, and startup 

preferences. To save, click the       icon 

or       to return to the main area and 

rooms menu.

Or select 

Add New User Role

 to define 

a user name, access level (guest 

or manager), manage permissions, 

views (shade, lighting, default, scene, 

partition), default view (shade, lighting, 

default, scene, partition, none), and 

startup preferences.

4. Appearance 

- Establish color palette, background color, and font size 

settings for optimal viewing.

5. Areas and Rooms 

- Manage areas 

by selecting an area to adjust its name, 

access, included scenes, favorites, 

room presets, and startup location.

If rooms and partitions have previously 

been established in Design Center, 

further customize each area, including 

partitioned areas within this setting.

Settings

Access and Permissions

Administrator

Add New User Role

Settings

Edit User Role

User Name

Access Level

Administrator

Administrator

Password

Management

Settings

Edit User Role

User Name

Access Level

Required

Management

Guest

Settings

Appearance

Color Palette

Background

Font Size

Settings

Edit Palette

Dark

Light

Dark Con...

Light Con...

Settings

Areas and Rooms

Main Floor

Theater Ga...

Theater

Game

Project

Settings

Edit Area

Area Name

Access

Main Floor

Included Scenes

Select Users

Manage

Summary of Contents for Wattstopper EQ41-LCAP

Page 1: ...er Ethernet PoE or PoE PoE optional Ethernet 4 Port PoE Injector part number DA2400 or COM POE SWITCH Communicates over Ethernet via Ethernet Bus Firmware upgradeable over Ethernet from Design Center Built in ambient light sensor for Active AUTO mode screen brightness Built in proximity activation 6 maximum may be programmed to execute a task with a hand wave across front of station Dual operation...

Page 2: ...on Yes Maximum Gangs Single gang only LCD Button Status Automatic white off orange on Mounting US European style single gang wall boxes or low voltage brackets Addressing Self addressing through software Finish Trim Titanium Touchscreen Black glass Glass Surface Chemically strengthened Ambient Operating Temperature 32 95 F 0 35 C Ambient Operating Humidity 5 95 non condensing CE FCC Compliant Yes ...

Page 3: ...tall station by rotating figure B and connecting the top first Press station in and hold on bottom center while securing the hex screw with provided allen wrench figure C Ethernet Bus Power and communication Ethernet PoE or PoE Optional Ethernet 4 Port PoE Injector part DA2400 EQUINOX 41 LCAP TOUCHSCREEN NETWORK PANEL OR SWITCH ETHERNET PoE or PoE Harv Open Rest Ge PoE PoE ETHERNET BUS SCREWS Use ...

Page 4: ...ed 1 First Time Setup Click on Create Admin Password to establish a custom password Using the keyboard type in a password and press check to confirm 2 Once the Admin Password is established press Initialize System to access the current default view with all on all off control 2 About Discover information about the Equinox 41 LCAP including serial number part number and application edition Also ide...

Page 5: ... color and font size settings for optimal viewing 5 Areas and Rooms Manage areas by selecting an area to adjust its name access included scenes favorites room presets and startup location If rooms and partitions have previously been established in Design Center further customize each area including partitioned areas within this setting Settings Access and Permissions Administrator Add New User Rol...

Page 6: ...evices Lights Shades Settings Devices Lights Shades Area1 Area1 New Partition Left Left Settings Area1 Lights Shades Load 1 Load 2 Load 3 Load 3 Load 3 Load 3 Settings Edit Light Name Access Load 1 Schedules Select Users Edit Settings Edit Event Event Name Scheduled Recurrence Required Every hour 0 Action None 8 Events An event starts a scene at a specific time and or date interval hourly daily we...

Page 7: ...ateway or DNS Server addresses 11 Repair Check status of items needing repair Create and manage categories to your specific project Second and third levels allow creation and management of load and shade groups Settings Project Add New Category Categories Settings Name Category Scenes Project Manage Categories Settings Network Settings 192 168 5 107 255 255 255 0 Netmask 192 168 5 1 Gateway DNS Se...

Page 8: ...n actions that are available to your system Settings Scenes Add New Scene Settings Edit Scene Scene Name Actions Required Edit Rooms Manage WIDGETS OVERVIEW Program complete system control including shades lighting home scenes and divide combine For detailed information about all widgets and settings refer to the widget instructions install pdf on the dealer site Shades Lighting Default Scenes 12 ...

Page 9: ...is 3 ans Les écrans tactiles sont garantis pendant 90 jours Wattstopper ne peut être tenu responsable de tout dommage consécutif causé par ou lié à l utilisation ou à la performance de ce produit ou tout autre dommage indirect lié à la perte de propriété de revenus ou de profits ou aux coûts d enlèvement d installation ou de réinstallation Wattstopper garantiza que sus productos están libres de de...